{"id":3315,"date":"2026-10-06T10:44:00","date_gmt":"2026-10-06T10:44:00","guid":{"rendered":"https:\/\/hmxenergy.com\/?p=3315"},"modified":"2026-10-04T00:50:20","modified_gmt":"2026-10-04T00:50:20","slug":"ev-charging-demand-charges-bess","status":"publish","type":"post","link":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/","title":{"rendered":"EV-Ladeleistungsspitzen: Zuerst den gleichzeitigen Spitzenwert modellieren"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1.jpg\" alt=\"BESS demand charge management EV charging: 120kW Dual - Gun Charging Pile Project 1\" class=\"wp-image-1084\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1.jpg 1000w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1-600x600.jpg 600w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1-100x100.jpg 100w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1-800x800.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1-300x300.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1-150x150.jpg 150w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1-768x768.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fast charging can create short, high site peaks. Where a tariff bills monthly demand, a battery may cap grid import during those events. The value depends on the exact billing rule and the operator\u2019s ability to recharge without creating a second peak.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A global battery-cost benchmark cannot replace a local cash-flow model. Charger use, tariff structure, grid upgrade cost and service obligations must be entered separately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr eine konkrete Pr\u00fcfung auf Ger\u00e4teebene wenden Sie die oben genannten Pr\u00fcfungen auf die <a href=\"https:\/\/hmxenergy.com\/de\/produkt\/energiespeicher-integrierte-ladestation\/\">100\/200kWh speicherintegrierte Ladel\u00f6sung<\/a> an und fordern Sie Best\u00e4tigung f\u00fcr die vorgesehenen Standortbedingungen und den Betriebsmodus an.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The general calculation sequence is set out in the <a href=\"https:\/\/hmxenergy.com\/de\/dimensionierung-von-peak-shaving-batterien\/\">Leitfaden zur Dimensionierung von Spitzenlastkappungsbatterien an<\/a>. For charging sites, replace the factory load series with session-level charger demand and retain the same tariff-interval discipline.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Direkte Antwort:<\/strong> Reproduce the utility bill from interval data before modelling storage. If the base model cannot match billed demand, the savings forecast is not ready for investment approval.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Recherchepr\u00fcfdatum: 4. Oktober 2026. Quantitative Aussagen sind mit der verlinkten Quelle verkn\u00fcpft und sollten erneut \u00fcberpr\u00fcft werden, falls die Beschaffung sp\u00e4ter erfolgt.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Der <a href=\"https:\/\/afdc.energy.gov\/fuels\/electricity-infrastructure-maintenance-and-operation\" target=\"_blank\" rel=\"noopener noreferrer\">Alternative Fuels Data Center guidance on charging-station operating costs<\/a> notes that DC fast charging is more likely than lower-power charging to trigger demand charges and describes demand as commonly based on the highest 15-minute average in the billing period. The project model should therefore reproduce the local tariff interval instead of smoothing sessions into hourly data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vor dem Design-Freeze sollte das Projektteam pr\u00fcfen <a href=\"https:\/\/www.energy.gov\/cmei\/femp\/evaluating-your-utility-rate-options\" target=\"_blank\" rel=\"noopener noreferrer\">DOE-Leitfaden zu Versorgungstarifen<\/a>. Versorgungsrechnungen k\u00f6nnen Energie-, Leistungs- und zeitabh\u00e4ngige Komponenten kombinieren, daher m\u00fcssen Einsparmodelle den tats\u00e4chlichen Tarif verwenden und nicht eine generische Hochtarif-\/Niedertarif-Spanne.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Reproduce the tariff demand interval<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For Commercial charging operators and site owners, the first task is to turn the intended service into measurable inputs and acceptance limits. The following table keeps the decision tied to evidence instead of a broad product label.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Model layer<\/th><th>Required data<\/th><th>Output<\/th><\/tr><\/thead><tbody><tr><td>Charging demand<\/td><td>Sessions, dwell time and power curve<\/td><td>Uncontrolled site load<\/td><\/tr><tr><td>Non-charging load<\/td><td>Building and auxiliary interval load<\/td><td>Total site demand<\/td><\/tr><tr><td>Tarif<\/td><td>Demand interval, ratchet and time periods<\/td><td>Baseline bill<\/td><\/tr><tr><td>Battery dispatch<\/td><td>Power, energy, reserve and recharge rule<\/td><td>Controlled grid load<\/td><\/tr><tr><td>Degradation and service<\/td><td>Cycles, throughput and maintenance<\/td><td>Lifecycle cost<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Demand-charge model<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-1024x683.jpg\" alt=\"BESS demand charge management EV charging: energy storage system for commercial building and shopping mall peak shaving backup power\" class=\"wp-image-2974\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-1024x683.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-300x200.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-768x512.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-18x12.jpg 18w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-800x533.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power.jpg 1536w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Dieselben Nachweis- und Abnahmefragen k\u00f6nnen verwendet werden, wenn HMXs <a href=\"https:\/\/hmxenergy.com\/de\/produktkategorie\/ladestationen-fur-elektrofahrzeuge\/\">Energiespeicher-Ladel\u00f6sungen<\/a>; bewertet wird; Kataloginformationen sollten mit dem kontrollierten Angebot und den Zeichnungen abgeglichen werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr die abschlie\u00dfende Nachweispr\u00fcfung verwenden Sie <a href=\"https:\/\/www.iea.org\/reports\/global-ev-outlook-2026\/electric-vehicle-charging-chap-6-and-10\" target=\"_blank\" rel=\"noopener noreferrer\">IEA Global EV Outlook 2026 Ladeanalyse<\/a> as a source check. IEA estimates more than 7 million public charging points at the end of 2025, after growth of more than 33% in one year; fast and ultra-fast points reached 2.2 million.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Replay charger sessions against the grid cap<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Das kommerzielle Angebot sollte seine Annahmen, Ausschl\u00fcsse und Messgrenzen angeben. K\u00e4ufer k\u00f6nnen Systeme dann auf derselben Basis vergleichen und sp\u00e4tere Design\u00e4nderungen unter Dokumentenkontrolle halten.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Scenario<\/th><th>Frage<\/th><th>Sensitivity<\/th><\/tr><\/thead><tbody><tr><td>Low utilisation<\/td><td>Are peaks rare but expensive?<\/td><td>Demand savings versus fixed cost<\/td><\/tr><tr><td>Growth case<\/td><td>How fast do sessions increase?<\/td><td>Expansion and grid limit<\/td><\/tr><tr><td>Back-to-back sessions<\/td><td>Can storage recover between peaks?<\/td><td>Recharge power<\/td><\/tr><tr><td>High tariff spread<\/td><td>Can recharge move off-peak?<\/td><td>Energy cost<\/td><\/tr><tr><td>Backup reserve<\/td><td>Must energy remain unused for outages?<\/td><td>Available shaving capacity<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Investment sensitivities<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Aktionspunkte f\u00fcr das Projektteam<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Run at least a base, growth and stress scenario.<\/li><li>Include months with special events or seasonal fleet peaks.<\/li><li>Do not count the same battery capacity fully for charging support, demand shaving and backup at the same time.<\/li><li>Use contractual availability and response requirements in the financial model.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr aktuellen Markt- und Politikkontext pr\u00fcfen Sie <a href=\"https:\/\/www.iea.org\/reports\/electricity-2026\/flexibility\" target=\"_blank\" rel=\"noopener noreferrer\">IEA Electricity 2026 Flexibilit\u00e4tsanalyse<\/a>. gepr\u00fcft werden. Die IEA identifiziert Batterien als vielseitige Quelle kurzfristiger Flexibilit\u00e4t im Stromsystem, aber die erforderliche Dauer h\u00e4ngt von der erbrachten Dienstleistung ab.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Where demand-charge models overstate savings<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">These are the practical objections and failure modes most likely to stop approval, delay commissioning or create an avoidable service call for Commercial charging operators and site owners.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>The baseline model cannot reproduce the billed demand.<\/li><li>A recharge event creates another peak in the same billing period.<\/li><li>Session growth is included in revenue but not in grid or battery stress.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Fragen, die der K\u00e4ufer vor der Genehmigung stellen sollte<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Which exact interval, ratchet and seasonal rules apply?<\/li><li>How does a back-to-back fast-charging day change the result?<\/li><li>What capacity remains unavailable because of backup reserve?<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Make the financial model reproduce operations and billing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Validate the tariff engine against actual invoices, including interval length, time periods, ratchets, minimums and seasonal rules. Combine charger sessions with the rest of the site load. The baseline should reproduce both monthly kWh and billed kW within an explained tolerance before storage dispatch is introduced.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eine verwandte HMX-Referenz ist die <a href=\"https:\/\/hmxenergy.com\/de\/produktkategorie\/gewerbe-und-industrie-energiespeicherung\/\">kommerzielle und industrielle Energiespeicherpalette<\/a>. Nutzen Sie sie, um die n\u00e4chste Lieferantendiskussion zu strukturieren, und dokumentieren Sie dann projektspezifische Abweichungen vor der Bestellung.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Simulate the battery with power, usable energy, reserve, efficiency, auxiliaries and recharge constraints. Review the state of charge after every high-demand event. Back-to-back sessions can exhaust the buffer, while aggressive recharge can set a new peak. The model should count target breaches rather than assuming every event is shaved successfully.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Der technische Vergleich sollte auch gegen <a href=\"https:\/\/www.irena.org\/Digital-Report\/Renewable-Power-Generation-Costs-in-2024\" target=\"_blank\" rel=\"noopener noreferrer\">IRENA Renewable Power Generation Costs in 2024<\/a>. IRENA berichtet f\u00fcr 2024 einen globalen durchschnittlichen installierten Kostenwert von USD 192\/kWh f\u00fcr netzgekoppelte Batteriespeicher, 93% unter 2010. K\u00e4ufer sollten diesen globalen Benchmark nicht als Projektangebot behandeln.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Present cash flow as scenarios, not one guaranteed saving. Include utilisation growth, tariff change, degradation, service, downtime and alternative grid work. If backup reserve is required, remove it from the economic dispatch window. The decision should compare the value of faster site deployment and managed grid demand with the full lifecycle obligation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Projekt-Workflow<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Reproduce historic bills from interval load and tariff rules.<\/li><li>Simulate sessions, recharge and reserve across complete months.<\/li><li>Run utilisation, tariff, degradation and availability sensitivities.<\/li><li>Tie investment approval to auditable assumptions and operating KPIs.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Die Berechnung reproduzierbar halten<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Roh-Z\u00e4hler- oder Lastdatei, das Bereinigungsprotokoll, Tarif- oder Betriebsregeln, die Modellversion und jede Annahme speichern, die Standortdaten in Leistung und Energie umrechnet. Der Eigent\u00fcmer sollte in der Lage sein, den Basisfall erneut auszuf\u00fchren, wenn sich Produktion, Tarife, Lasten oder Reservepolitik \u00e4ndern, anstatt das urspr\u00fcngliche Ergebnis als dauerhaft zu behandeln.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">K\u00e4ufer, die den anf\u00e4nglichen Umfang definieren, k\u00f6nnen diese Anforderungen mit HMX\u2019s <a href=\"https:\/\/hmxenergy.com\/de\/projekte\/zugeschnitten-auf-malaysische-fabriken-spitzenlastkappung-eigenverbrauch-mgc-konformitat\/\">Malaysia-Fabrik-Speicherprojekt<\/a>. vergleichen. Die Seite ist eine Produkt- oder Projektreferenz; die endg\u00fcltige Eignung erfordert weiterhin eine schriftliche Projektspezifikation.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Roh- und bereinigte Zeitreihendaten mit dokumentierter Zeitzone und dokumentiertem Intervall.<\/li><li>Basis-, Wachstums- und Stressszenarien mit Verlust-, Reserve- und Degradationsinputs.<\/li><li>Ausgew\u00e4hlte Regelungssollwerte und der Grund, warum abgelehnte Alternativen nicht gew\u00e4hlt wurden.<\/li><li>Ein Inbetriebnahme-Trace, der das Modell mit dem gemessenen Standortverhalten verbindet.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bei der \u00dcbergabe dem Eigent\u00fcmer die Modellinputs und einen Aktualisierungsausl\u00f6ser geben. Eine wesentliche \u00c4nderung von Tarif, Last, Produktion, Wetter oder Reserve sollte zu einem kontrollierten erneuten Durchlauf f\u00fchren, anstatt zu einem ungest\u00fctzten Versprechen, dass die urspr\u00fcngliche Einsparung oder Laufzeit weiterhin gilt.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"759\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-1024x759.jpg\" alt=\"BESS demand charge management EV charging: Completed 100kW 215kWh C&amp;I solar energy\u2011storage project for Malaysia factory, peak shaving, backup power solution for industrial plant\" class=\"wp-image-3161\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-1024x759.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-300x222.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-768x569.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-1536x1139.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-2048x1518.jpg 2048w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-16x12.jpg 16w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-800x593.jpg 800w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Kommerzieller Test<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Investition erst genehmigen, wenn das Betriebsmodell die aktuelle Rechnung oder Dienstleistungsbeschr\u00e4nkung reproduziert und auch unter einem angemessenen Belastungsszenario funktioniert.<\/p>","protected":false},"excerpt":{"rendered":"<p>Model BESS demand-charge management at EV hubs from billing intervals, charger sessions, grid limits, recharge timing and battery reserve.<\/p>","protected":false},"author":4,"featured_media":1084,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3315","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"HMX ENERGY\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"HMX Energy Co., Ltd -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"EV Charging Demand Charges: Model the Coincident Peak First\" \/>\n\t\t<meta property=\"og:description\" content=\"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"740\" \/>\n\t\t<meta property=\"og:image:height\" content=\"495\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-06T10:44:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-04T00:50:20+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"EV Charging Demand Charges: Model the Coincident Peak First\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#blogposting\",\"name\":\"EV Charging Demand Charges: Model the Coincident Peak First\",\"headline\":\"EV Charging Demand Charges: Model the Coincident Peak First\",\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/author\\\/hmxenergy\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/120kW-Dual-Gun-Charging-Pile-Project-1.jpg\",\"width\":1000,\"height\":1000},\"datePublished\":\"2026-10-06T10:44:00+00:00\",\"dateModified\":\"2026-10-04T00:50:20+00:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#webpage\"},\"articleSection\":\"Blog&amp;News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog&amp;News\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#listItem\",\"name\":\"EV Charging Demand Charges: Model the Coincident Peak First\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#listItem\",\"position\":3,\"name\":\"EV Charging Demand Charges: Model the Coincident Peak First\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#organization\",\"name\":\"HMX Energy Co., Ltd\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/\",\"telephone\":\"+8613310869219\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/HM-logo.png\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#organizationLogo\",\"width\":740,\"height\":495,\"caption\":\"HM logo\"},\"image\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/people\\\/Huiming-green-ennergy\\\/100091938723333\\\/\",\"https:\\\/\\\/www.instagram.com\\\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/shenzhen-hmx-new-energy-co-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/author\\\/hmxenergy\\\/#author\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/author\\\/hmxenergy\\\/\",\"name\":\"HMX ENERGY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#webpage\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/\",\"name\":\"EV Charging Demand Charges: Model the Coincident Peak First\",\"description\":\"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/author\\\/hmxenergy\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/author\\\/hmxenergy\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/120kW-Dual-Gun-Charging-Pile-Project-1.jpg\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#mainImage\",\"width\":1000,\"height\":1000},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/ev-charging-demand-charges-bess\\\/#mainImage\"},\"datePublished\":\"2026-10-06T10:44:00+00:00\",\"dateModified\":\"2026-10-04T00:50:20+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/\",\"name\":\"HMX Energy Co., Ltd\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"EV-Ladeleistungsspitzen: Zuerst den gleichzeitigen Spitzenwert modellieren","description":"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.","canonical_url":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#blogposting","name":"EV Charging Demand Charges: Model the Coincident Peak First","headline":"EV Charging Demand Charges: Model the Coincident Peak First","author":{"@id":"https:\/\/hmxenergy.com\/de\/author\/hmxenergy\/#author"},"publisher":{"@id":"https:\/\/hmxenergy.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1.jpg","width":1000,"height":1000},"datePublished":"2026-10-06T10:44:00+00:00","dateModified":"2026-10-04T00:50:20+00:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#webpage"},"isPartOf":{"@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#webpage"},"articleSection":"Blog&amp;News"},{"@type":"BreadcrumbList","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/#listItem","position":1,"name":"Home","item":"https:\/\/hmxenergy.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/category\/blog\/#listItem","name":"Blog&amp;News"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/category\/blog\/#listItem","position":2,"name":"Blog&amp;News","item":"https:\/\/hmxenergy.com\/de\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#listItem","name":"EV Charging Demand Charges: Model the Coincident Peak First"},"previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#listItem","position":3,"name":"EV Charging Demand Charges: Model the Coincident Peak First","previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/de\/category\/blog\/#listItem","name":"Blog&amp;News"}}]},{"@type":"Organization","@id":"https:\/\/hmxenergy.com\/de\/#organization","name":"HMX Energy Co., Ltd","url":"https:\/\/hmxenergy.com\/de\/","telephone":"+8613310869219","logo":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#organizationLogo","width":740,"height":495,"caption":"HM logo"},"image":{"@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","https:\/\/www.instagram.com\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr","https:\/\/www.linkedin.com\/company\/shenzhen-hmx-new-energy-co-ltd\/"]},{"@type":"Person","@id":"https:\/\/hmxenergy.com\/de\/author\/hmxenergy\/#author","url":"https:\/\/hmxenergy.com\/de\/author\/hmxenergy\/","name":"HMX ENERGY"},{"@type":"WebPage","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#webpage","url":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/","name":"EV Charging Demand Charges: Model the Coincident Peak First","description":"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/hmxenergy.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#breadcrumblist"},"author":{"@id":"https:\/\/hmxenergy.com\/de\/author\/hmxenergy\/#author"},"creator":{"@id":"https:\/\/hmxenergy.com\/de\/author\/hmxenergy\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/07\/120kW-Dual-Gun-Charging-Pile-Project-1.jpg","@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#mainImage","width":1000,"height":1000},"primaryImageOfPage":{"@id":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/#mainImage"},"datePublished":"2026-10-06T10:44:00+00:00","dateModified":"2026-10-04T00:50:20+00:00"},{"@type":"WebSite","@id":"https:\/\/hmxenergy.com\/de\/#website","url":"https:\/\/hmxenergy.com\/de\/","name":"HMX Energy Co., Ltd","inLanguage":"de-DE","publisher":{"@id":"https:\/\/hmxenergy.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"HMX Energy Co., Ltd -","og:type":"article","og:title":"EV Charging Demand Charges: Model the Coincident Peak First","og:description":"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.","og:url":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/","og:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:secure_url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:width":740,"og:image:height":495,"article:published_time":"2026-10-06T10:44:00+00:00","article:modified_time":"2026-10-04T00:50:20+00:00","article:publisher":"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","twitter:card":"summary_large_image","twitter:title":"EV Charging Demand Charges: Model the Coincident Peak First","twitter:description":"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.","twitter:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png"},"aioseo_meta_data":{"post_id":"3315","title":"EV-Ladeleistungsspitzen: Zuerst den gleichzeitigen Spitzenwert modellieren","description":"Model EV charging demand charges using the actual billing interval, coincident sessions, grid cap, battery recharge and tariff ratchet before sizing BESS.","keywords":null,"keyphrases":{"focus":{"keyphrase":"BESS demand charge management EV charging","score":0,"analysis":[]},"additional":[]},"focus_keyword":"BESS demand charge management EV charging","additional_keywords":null,"truseo_locale":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-30 03:34:22","updated":"2026-10-06 12:13:10"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/de\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/de\/category\/blog\/\" title=\"Blog&amp;News\">Blog&amp;News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tEV Charging Demand Charges: Model the Coincident Peak First\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/hmxenergy.com\/de\/"},{"label":"Blog&amp;News","link":"https:\/\/hmxenergy.com\/de\/category\/blog\/"},{"label":"EV Charging Demand Charges: Model the Coincident Peak First","link":"https:\/\/hmxenergy.com\/de\/ev-charging-demand-charges-bess\/"}],"_links":{"self":[{"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/posts\/3315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/comments?post=3315"}],"version-history":[{"count":7,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/posts\/3315\/revisions"}],"predecessor-version":[{"id":3485,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/posts\/3315\/revisions\/3485"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/media\/1084"}],"wp:attachment":[{"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/media?parent=3315"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/categories?post=3315"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hmxenergy.com\/de\/wp-json\/wp\/v2\/tags?post=3315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}