{"id":3285,"date":"2026-10-01T12:26:00","date_gmt":"2026-10-01T12:26:00","guid":{"rendered":"https:\/\/hmxenergy.com\/?p=3285"},"modified":"2026-10-04T00:40:40","modified_gmt":"2026-10-04T00:40:40","slug":"dimensionamiento-de-bateria-para-aplanamiento-de-picos","status":"publish","type":"post","link":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/","title":{"rendered":"Dimensionamiento de bater\u00edas para reducci\u00f3n de picos: comenzar con datos de carga de 15 minutos"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"759\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-1024x759.jpg\" alt=\"dimensionamiento de bater\u00eda para peak shaving: Proyecto completado de almacenamiento de energ\u00eda solar C&amp;I de 100kW 215kWh para f\u00e1brica en Malasia, peak shaving, soluci\u00f3n de energ\u00eda de respaldo para planta industrial\" class=\"wp-image-3161\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-1024x759.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-300x222.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-768x569.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-1536x1139.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-2048x1518.jpg 2048w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-16x12.jpg 16w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-800x593.jpg 800w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La reducci\u00f3n de picos es primero un problema de potencia y segundo un problema de energ\u00eda. La potencia nominal debe cubrir el exceso de carga por encima del objetivo; la energ\u00eda utilizable debe sostener esa reducci\u00f3n durante todo el evento de pico, incluyendo las p\u00e9rdidas de conversi\u00f3n y la reserva operativa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una factura mensual rara vez muestra suficiente detalle. El dimensionamiento debe comenzar con datos de demanda por intervalos y las reglas tarifarias exactas utilizadas para calcular la demanda facturada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una referencia relacionada de HMX es la <a href=\"https:\/\/hmxenergy.com\/es\/categoria-producto\/almacenamiento-de-energia-comercial-e-industrial\/\">gama de almacenamiento de energ\u00eda comercial e industrial<\/a>. Util\u00edcela para enmarcar la pr\u00f3xima conversaci\u00f3n con el proveedor, luego registre las desviaciones espec\u00edficas del proyecto antes de realizar el pedido.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Respuesta directa:<\/strong> Utilice al menos un a\u00f1o completo de datos por intervalos. Identifique los picos recurrentes, los eventos excepcionales y los cambios estacionales de producci\u00f3n antes de elegir el l\u00edmite de demanda objetivo.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Fecha de revisi\u00f3n de la investigaci\u00f3n: 30 de septiembre de 2026. Las declaraciones cuantitativas est\u00e1n vinculadas a la fuente enlazada y deben verificarse nuevamente si la adquisici\u00f3n ocurre m\u00e1s tarde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para el trabajo de especificaci\u00f3n y aceptaci\u00f3n, <a href=\"https:\/\/www.energy.gov\/cmei\/femp\/evaluating-your-utility-rate-options\" target=\"_blank\" rel=\"noopener noreferrer\">Gu\u00eda de tarifas de servicios p\u00fablicos del DOE<\/a> proporciona una referencia independiente. Las facturas de servicios p\u00fablicos pueden combinar componentes de energ\u00eda, demanda y tiempo de uso, por lo que los modelos de ahorro deben utilizar la tarifa real en lugar de un diferencial gen\u00e9rico pico\/fuera de pico.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Definir el alcance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para f\u00e1bricas y EPCs comerciales e industriales en mercados impulsados por tarifas, la primera tarea es convertir el servicio previsto en entradas medibles y l\u00edmites de aceptaci\u00f3n. La siguiente tabla mantiene la decisi\u00f3n vinculada a la evidencia en lugar de a una etiqueta amplia de producto.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Entrada<\/th><th>Unidad<\/th><th>Uso en el modelo<\/th><\/tr><\/thead><tbody><tr><td>Carga de la instalaci\u00f3n por intervalos<\/td><td>kW por marca de tiempo<\/td><td>Determinar la magnitud y la duraci\u00f3n del pico<\/td><\/tr><tr><td>Regla de demanda facturable<\/td><td>kW y duraci\u00f3n del intervalo<\/td><td>Reproducir la factura de servicios p\u00fablicos<\/td><\/tr><tr><td>L\u00edmite objetivo de la red<\/td><td>kW<\/td><td>Establecer el comando de descarga<\/td><\/tr><tr><td>Duraci\u00f3n del pico<\/td><td>horas<\/td><td>Calcular los kWh utilizables requeridos<\/td><\/tr><tr><td>P\u00e9rdidas del sistema y reserva<\/td><td>porcentaje o kWh<\/td><td>Convertir el requisito utilizable en capacidad instalada<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Entradas de dimensionamiento para reducci\u00f3n de picos<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"769\" height=\"1024\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving-769x1024.jpg\" alt=\"dimensionamiento de bater\u00eda para peak shaving: Estructura interna del gabinete de almacenamiento de energ\u00eda de enfriamiento por aire de alta eficiencia para la soluci\u00f3n de peak shaving de f\u00e1brica en Bangladesh de 300kW 645kWh\" class=\"wp-image-3174\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving-769x1024.jpg 769w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving-225x300.jpg 225w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving-768x1023.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving-9x12.jpg 9w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving-800x1066.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/high-efficiency-air-cooling-energy-storage-solution-300kw645kwh-for-bangladesh-factory-peak-shaving.jpg 1081w\" sizes=\"(max-width: 769px) 100vw, 769px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Los compradores que definen el alcance inicial pueden comparar estos requisitos con los de HMX <a href=\"https:\/\/hmxenergy.com\/es\/producto\/ehmg008-sistema-de-almacenamiento-de-energia-refrigerado-por-aire-de-100kw-215kwh\/\">sistema enfriado por aire de 100kW\/215kWh<\/a>. La p\u00e1gina es una referencia de producto o proyecto; la idoneidad final a\u00fan requiere una especificaci\u00f3n de proyecto por escrito.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de la congelaci\u00f3n del dise\u00f1o, el equipo del proyecto debe revisar <a href=\"https:\/\/www.iea.org\/reports\/electricity-2026\/flexibility\" target=\"_blank\" rel=\"noopener noreferrer\">An\u00e1lisis de flexibilidad de IEA Electricity 2026<\/a>. La IEA identifica las bater\u00edas como una fuente vers\u00e1til de flexibilidad a corto plazo del sistema el\u00e9ctrico, pero la duraci\u00f3n requerida depende del servicio que se presta.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pruebas de aceptaci\u00f3n y fallo<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La oferta comercial debe indicar sus supuestos, exclusiones y l\u00edmite de medici\u00f3n. Los compradores pueden entonces comparar sistemas sobre la misma base y mantener los cambios de dise\u00f1o posteriores bajo control documental.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Paso de ejemplo<\/th><th>C\u00e1lculo<\/th><th>Significado del resultado<\/th><\/tr><\/thead><tbody><tr><td>Requisito de potencia<\/td><td>Pico medido menos l\u00edmite objetivo de la red<\/td><td>Potencia m\u00ednima de descarga del PCS<\/td><\/tr><tr><td>Energ\u00eda del evento<\/td><td>Suma de la carga en exceso a lo largo de los intervalos de pico<\/td><td>Energ\u00eda de descarga utilizable<\/td><\/tr><tr><td>Margen operativo<\/td><td>Energ\u00eda del evento m\u00e1s reserva y p\u00e9rdidas<\/td><td>Energ\u00eda disponible requerida<\/td><\/tr><tr><td>N\u00famero de ciclos<\/td><td>N\u00famero de eventos de despacho por a\u00f1o<\/td><td>Entrada para garant\u00eda y degradaci\u00f3n<\/td><\/tr><tr><td>Verificaci\u00f3n de ahorros<\/td><td>Cargo por demanda evitado menos costos de energ\u00eda y servicio<\/td><td>Valor del proyecto antes del financiamiento<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Secuencia de c\u00e1lculo sin valores tarifarios inventados<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Puntos de acci\u00f3n para el equipo del proyecto<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Modele exactamente el intervalo de demanda de la empresa de servicios p\u00fablicos; una regla de 15 minutos y una regla de 30 minutos pueden producir necesidades de despacho diferentes.<\/li><li>Mantenga la reserva de respaldo separada de la energ\u00eda asignada al despacho econ\u00f3mico.<\/li><li>Pruebe la estrategia de control en d\u00edas con m\u00faltiples picos.<\/li><li>Utilice una tabla de sensibilidad para el crecimiento de la producci\u00f3n, los cambios tarifarios y la degradaci\u00f3n de la bater\u00eda.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para la revisi\u00f3n final de evidencias, utilizar <a href=\"https:\/\/www.energy.gov\/cmei\/femp\/articles\/battery-energy-storage-system-procurement-checklist\" target=\"_blank\" rel=\"noopener noreferrer\">Lista de verificaci\u00f3n de adquisici\u00f3n de BESS del DOE de EE. UU.<\/a> como verificaci\u00f3n de fuente. La lista de verificaci\u00f3n del Departamento de Energ\u00eda de EE. UU. separa el desarrollo temprano del proyecto, las especificaciones t\u00e9cnicas y los trabajos de interconexi\u00f3n para sistemas comerciales de litio-ion.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Por qu\u00e9 decepcionan los ahorros por reducci\u00f3n de picos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Estas son las objeciones pr\u00e1cticas y los modos de fallo con mayor probabilidad de impedir la aprobaci\u00f3n, retrasar la puesta en marcha o generar una visita de servicio evitable para F\u00e1bricas y EPCs C&amp;I en mercados impulsados por tarifas.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Se utiliza una factura mensual en lugar de datos de demanda por intervalos.<\/li><li>La recarga crea un segundo pico facturado m\u00e1s tarde en el d\u00eda.<\/li><li>La misma reserva de bater\u00eda se contabiliza tanto para respaldo como para despacho econ\u00f3mico.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Preguntas que el comprador debe formular antes de la aprobaci\u00f3n<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00bfPuede el modelo reproducir la factura actual antes de a\u00f1adir el almacenamiento?<\/li><li>\u00bfCu\u00e1ntos picos separados ocurren en los peores d\u00edas de operaci\u00f3n?<\/li><li>\u00bfQu\u00e9 trinquete tarifario, intervalo de facturaci\u00f3n y regla estacional determina el resultado?<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Convertir los datos por intervalos en un dise\u00f1o despachable<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Limpiar al menos doce meses de datos por intervalos antes del dimensionamiento. Marcar paradas, cambios de medidor, intervalos faltantes, ampliaciones de producci\u00f3n y eventos excepcionales. Recrear la demanda facturada a partir de la regla de la utility y comparar el modelo con las facturas. Si la l\u00ednea base no coincide con la factura, a\u00f1adir una bater\u00eda solo hace que el error sea m\u00e1s dif\u00edcil de encontrar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para una revisi\u00f3n concreta a nivel de equipo, aplique las comprobaciones anteriores al <a href=\"https:\/\/hmxenergy.com\/es\/producto\/ehmg008-sistema-de-almacenamiento-de-energia-refrigerado-por-aire-de-150kw-y-315kwh\/\">Sistema enfriado por aire de 150kW\/315kWh<\/a> y solicite confirmaci\u00f3n para las condiciones del sitio y el modo de operaci\u00f3n previstos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para cada intervalo, calcular la carga por encima del l\u00edmite de red propuesto. El exceso m\u00e1s alto determina la potencia de descarga requerida, mientras que la suma de energ\u00eda excedente durante el evento determina los kWh utilizables. Luego a\u00f1adir p\u00e9rdidas de conversi\u00f3n, demanda auxiliar, margen de control y la reserva de estado de carga. Repetir el c\u00e1lculo para d\u00edas con varios picos, porque la bater\u00eda puede no tener suficiente tiempo o capacidad de red para recargarse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para el contexto actual de mercado y pol\u00edticas, revisar <a href=\"https:\/\/www.irena.org\/Digital-Report\/Renewable-Power-Generation-Costs-in-2024\" target=\"_blank\" rel=\"noopener noreferrer\">IRENA Renewable Power Generation Costs in 2024<\/a>. IRENA reporta un costo instalado promedio global 2024 de USD 192\/kWh para almacenamiento en bater\u00edas a escala de utility, 93% por debajo de 2010. Los compradores no deben tratar ese benchmark global como una cotizaci\u00f3n de proyecto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">No optimizar un solo a\u00f1o hist\u00f3rico y llamar al resultado definitivo. Ejecutar casos de crecimiento de producci\u00f3n, tarifa, degradaci\u00f3n, clima m\u00e1s c\u00e1lido y menor disponibilidad. Mantener la reserva de respaldo separada y probar qu\u00e9 sucede cuando un corte sigue a un despacho econ\u00f3mico. El caso de inversi\u00f3n debe mostrar el ahorro por demanda, la energ\u00eda de recarga a\u00f1adida, el costo de servicio y cualquier pico objetivo no atendido en lugar de reportar solo un payback simple.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flujo de trabajo del proyecto<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Validar marcas de tiempo por intervalos, zona horaria, unidades del medidor y registros faltantes.<\/li><li>Reproducir el c\u00e1lculo de demanda de la utility antes de simular el almacenamiento.<\/li><li>Probar a\u00f1os base, de crecimiento y de estr\u00e9s con restricciones de reserva y degradaci\u00f3n.<\/li><li>Convertir el despacho seleccionado en requisitos de aceptaci\u00f3n de PCS, energ\u00eda utilizable y EMS.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Verificaci\u00f3n comercial adicional<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La prueba de aceptaci\u00f3n del EMS debe reproducir trazas de carga representativas o usar una prueba controlada en sitio. Registrar el setpoint de demanda, retardo de respuesta, ubicaci\u00f3n de medici\u00f3n, l\u00edmites de la bater\u00eda y regla de recarga. Incluir una alarma por reserva insuficiente o potencia no disponible para que el operador pueda distinguir una limitaci\u00f3n de control de una falla de equipo. Despu\u00e9s de los primeros ciclos de facturaci\u00f3n, comparar la demanda medida, la energ\u00eda de despacho, el costo de recarga y los eventos no disponibles con el modelo. Usar esa revisi\u00f3n para ajustar el objetivo sin violar la garant\u00eda o la reserva de respaldo. Un proyecto exitoso necesita una revisi\u00f3n operativa, no solo un certificado de puesta en marcha.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Mantener el c\u00e1lculo reproducible<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Guardar el archivo crudo del medidor o de carga, el registro de limpieza, la tarifa o reglas operativas, la versi\u00f3n del modelo y cada supuesto que convierte los datos del sitio en potencia y energ\u00eda. El propietario deber\u00eda poder volver a ejecutar el caso base cuando cambien la producci\u00f3n, las tarifas, las cargas o la pol\u00edtica de reserva en lugar de tratar el resultado original como permanente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las mismas preguntas de evidencia y aceptaci\u00f3n pueden usarse al evaluar los <a href=\"https:\/\/hmxenergy.com\/es\/proyectos\/adaptado-para-fabricas-malasias-recorte-de-picos-autoconsumo-cumplimiento-de-mgc\/\">Proyecto de almacenamiento en f\u00e1brica de Malasia<\/a>; de HMX; la informaci\u00f3n del cat\u00e1logo debe conciliarse con la cotizaci\u00f3n controlada y los planos.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Datos de series temporales crudos y limpios con zona horaria e intervalo documentados.<\/li><li>Escenarios base, de crecimiento y de estr\u00e9s con entradas de p\u00e9rdidas, reserva y degradaci\u00f3n.<\/li><li>Setpoints de control seleccionados y la raz\u00f3n por la que no se eligieron las alternativas rechazadas.<\/li><li>Una traza de puesta en marcha que conecte el modelo con el comportamiento medido del sitio.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En la entrega, dar al propietario las entradas del modelo y un disparador de actualizaci\u00f3n. Un cambio material en tarifa, carga, producci\u00f3n, clima o reserva deber\u00eda llevar a una reejecuci\u00f3n controlada en lugar de una promesa no respaldada de que el ahorro o runtime original todav\u00eda aplica.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-1024x683.jpg\" alt=\"dimensionamiento de bater\u00eda para peak shaving: sistema de almacenamiento de energ\u00eda para edificio comercial y peak shaving de centro comercial con energ\u00eda de respaldo\" class=\"wp-image-2974\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-1024x683.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-300x200.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-768x512.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-18x12.jpg 18w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power-800x533.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/energy-storage-system-for-commercial-building-and-shopping-mall-peak-shaving-backup-power.jpg 1536w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Visi\u00f3n de cierre<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El resultado \u00fatil del estudio no es un \u00fanico tama\u00f1o de bater\u00eda. Es un modelo repetible con entradas declaradas, sensibilidades y una prueba de aceptaci\u00f3n que el propietario pueda auditar.<\/p>","protected":false},"excerpt":{"rendered":"<p>Dimensionar una bater\u00eda de recorte de picos en f\u00e1brica a partir de la carga por intervalos, las ventanas tarifarias, la reducci\u00f3n objetivo en kW, la duraci\u00f3n de descarga y la reserva operativa.<\/p>","protected":false},"author":4,"featured_media":3161,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3285","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"HMX ENERGY\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"HMX Energy Co., Ltd -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\" \/>\n\t\t<meta property=\"og:description\" content=\"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"740\" \/>\n\t\t<meta property=\"og:image:height\" content=\"495\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-01T12:26:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-04T00:40:40+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#blogposting\",\"name\":\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\",\"headline\":\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\",\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Completed-100kW-215kWh-CI-solar-energy\\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-scaled.jpg\",\"width\":2560,\"height\":1898,\"caption\":\"Completed 100kW 215kWh C&I solar energy\\u2011storage project for Malaysia factory, peak shaving, backup power solution for industrial plant\"},\"datePublished\":\"2026-10-01T12:26:00+00:00\",\"dateModified\":\"2026-10-04T00:40:40+00:00\",\"inLanguage\":\"es-CL\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#webpage\"},\"articleSection\":\"Blog&amp;News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog&amp;News\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#listItem\",\"name\":\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#listItem\",\"position\":3,\"name\":\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#organization\",\"name\":\"HMX Energy Co., Ltd\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/\",\"telephone\":\"+8613310869219\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/HM-logo.png\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#organizationLogo\",\"width\":740,\"height\":495,\"caption\":\"HM logo\"},\"image\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/people\\\/Huiming-green-ennergy\\\/100091938723333\\\/\",\"https:\\\/\\\/www.instagram.com\\\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/shenzhen-hmx-new-energy-co-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/\",\"name\":\"HMX ENERGY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#webpage\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/\",\"name\":\"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data\",\"description\":\"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.\",\"inLanguage\":\"es-CL\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Completed-100kW-215kWh-CI-solar-energy\\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-scaled.jpg\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#mainImage\",\"width\":2560,\"height\":1898,\"caption\":\"Completed 100kW 215kWh C&I solar energy\\u2011storage project for Malaysia factory, peak shaving, backup power solution for industrial plant\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/peak-shaving-battery-sizing\\\/#mainImage\"},\"datePublished\":\"2026-10-01T12:26:00+00:00\",\"dateModified\":\"2026-10-04T00:40:40+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/\",\"name\":\"HMX Energy Co., Ltd\",\"inLanguage\":\"es-CL\",\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Dimensionamiento de bater\u00edas para reducci\u00f3n de picos: comenzar con datos de carga de 15 minutos","description":"Dimensionar una bater\u00eda de afeitado de picos a partir de la demanda por intervalos, la ventana de facturaci\u00f3n tarifaria, el l\u00edmite objetivo de la red, las restricciones de recarga, las p\u00e9rdidas y la reserva operativa.","canonical_url":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#blogposting","name":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","headline":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","author":{"@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author"},"publisher":{"@id":"https:\/\/hmxenergy.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-scaled.jpg","width":2560,"height":1898,"caption":"Completed 100kW 215kWh C&I solar energy\u2011storage project for Malaysia factory, peak shaving, backup power solution for industrial plant"},"datePublished":"2026-10-01T12:26:00+00:00","dateModified":"2026-10-04T00:40:40+00:00","inLanguage":"es-CL","mainEntityOfPage":{"@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#webpage"},"isPartOf":{"@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#webpage"},"articleSection":"Blog&amp;News"},{"@type":"BreadcrumbList","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/hmxenergy.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/category\/blog\/#listItem","name":"Blog&amp;News"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/category\/blog\/#listItem","position":2,"name":"Blog&amp;News","item":"https:\/\/hmxenergy.com\/es\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#listItem","name":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data"},"previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#listItem","position":3,"name":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/category\/blog\/#listItem","name":"Blog&amp;News"}}]},{"@type":"Organization","@id":"https:\/\/hmxenergy.com\/es\/#organization","name":"HMX Energy Co., Ltd","url":"https:\/\/hmxenergy.com\/es\/","telephone":"+8613310869219","logo":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#organizationLogo","width":740,"height":495,"caption":"HM logo"},"image":{"@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","https:\/\/www.instagram.com\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr","https:\/\/www.linkedin.com\/company\/shenzhen-hmx-new-energy-co-ltd\/"]},{"@type":"Person","@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author","url":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/","name":"HMX ENERGY"},{"@type":"WebPage","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#webpage","url":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/","name":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","description":"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.","inLanguage":"es-CL","isPartOf":{"@id":"https:\/\/hmxenergy.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#breadcrumblist"},"author":{"@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author"},"creator":{"@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Completed-100kW-215kWh-CI-solar-energy\u2011storage-project-for-Malaysia-factory-peak-shaving-backup-power-solution-for-industrial-plant-scaled.jpg","@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#mainImage","width":2560,"height":1898,"caption":"Completed 100kW 215kWh C&I solar energy\u2011storage project for Malaysia factory, peak shaving, backup power solution for industrial plant"},"primaryImageOfPage":{"@id":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/#mainImage"},"datePublished":"2026-10-01T12:26:00+00:00","dateModified":"2026-10-04T00:40:40+00:00"},{"@type":"WebSite","@id":"https:\/\/hmxenergy.com\/es\/#website","url":"https:\/\/hmxenergy.com\/es\/","name":"HMX Energy Co., Ltd","inLanguage":"es-CL","publisher":{"@id":"https:\/\/hmxenergy.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"HMX Energy Co., Ltd -","og:type":"article","og:title":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","og:description":"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.","og:url":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/","og:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:secure_url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:width":740,"og:image:height":495,"article:published_time":"2026-10-01T12:26:00+00:00","article:modified_time":"2026-10-04T00:40:40+00:00","article:publisher":"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","twitter:card":"summary_large_image","twitter:title":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","twitter:description":"Size a peak-shaving battery from interval demand, the tariff billing window, target grid limit, recharge constraints, losses and operating reserve.","twitter:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png"},"aioseo_meta_data":{"post_id":"3285","title":"Dimensionamiento de bater\u00edas para reducci\u00f3n de picos: comenzar con datos de carga de 15 minutos","description":"Dimensionar una bater\u00eda de afeitado de picos a partir de la demanda por intervalos, la ventana de facturaci\u00f3n tarifaria, el l\u00edmite objetivo de la red, las restricciones de recarga, las p\u00e9rdidas y la reserva operativa.","keywords":null,"keyphrases":{"focus":{"keyphrase":"peak shaving battery sizing","score":0,"analysis":[]},"additional":[]},"focus_keyword":"peak shaving battery sizing","additional_keywords":null,"truseo_locale":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-30 03:33:19","updated":"2026-10-04 01:24:17"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/es\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/es\/category\/blog\/\" title=\"Blog&amp;News\">Blog&amp;News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tPeak-Shaving Battery Sizing: Start with 15-Minute Load Data\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/hmxenergy.com\/es\/"},{"label":"Blog&amp;News","link":"https:\/\/hmxenergy.com\/es\/category\/blog\/"},{"label":"Peak-Shaving Battery Sizing: Start with 15-Minute Load Data","link":"https:\/\/hmxenergy.com\/es\/peak-shaving-battery-sizing\/"}],"_links":{"self":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts\/3285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/comments?post=3285"}],"version-history":[{"count":6,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts\/3285\/revisions"}],"predecessor-version":[{"id":3443,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts\/3285\/revisions\/3443"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/media\/3161"}],"wp:attachment":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/media?parent=3285"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/categories?post=3285"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/tags?post=3285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}