{"id":3301,"date":"2026-10-04T08:22:00","date_gmt":"2026-10-04T08:22:00","guid":{"rendered":"https:\/\/hmxenergy.com\/?p=3301"},"modified":"2026-10-04T00:50:08","modified_gmt":"2026-10-04T00:50:08","slug":"dimensionamiento-del-mppt-del-inversor-hibrido","status":"publish","type":"post","link":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/","title":{"rendered":"Dimensionamiento del MPPT del inversor h\u00edbrido: Voc en fr\u00edo, Vmp en caliente y corriente"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"778\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-1024x778.jpg\" alt=\"Dimensionamiento del MPPT del inversor h\u00edbrido: Caso de instalaci\u00f3n real de inversor solar h\u00edbrido, proyecto residencial de almacenamiento solar en villa en Filipinas\" class=\"wp-image-2702\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-1024x778.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-300x228.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-768x584.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-1536x1167.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-2048x1556.jpg 2048w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-16x12.jpg 16w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines-800x608.jpg 800w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">El dise\u00f1o de la cadena fotovoltaica debe permanecer dentro de los l\u00edmites de tensi\u00f3n y corriente del inversor en todas las temperaturas reales del m\u00f3dulo. Una cadena que parece aceptable en condiciones de prueba est\u00e1ndar puede exceder la tensi\u00f3n m\u00e1xima de CC en una ma\u00f1ana fr\u00eda o caer por debajo de la ventana del MPPT cuando los m\u00f3dulos est\u00e1n calientes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El c\u00e1lculo tambi\u00e9n necesita el n\u00famero de seguidores, las entradas por seguidor y cualquier regla de reparto de corriente indicada por el fabricante del inversor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para una revisi\u00f3n concreta a nivel de equipo, aplique las comprobaciones anteriores al <a href=\"https:\/\/hmxenergy.com\/es\/categoria-producto\/inversor-solar\/\">gama de inversores solares<\/a> y solicite confirmaci\u00f3n para las condiciones del sitio y el modo de operaci\u00f3n previstos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para sistemas que deben operar fuera de la red, combine el c\u00e1lculo de la cadena aqu\u00ed con el m\u00e9todo de balance energ\u00e9tico horario en la <a href=\"https:\/\/hmxenergy.com\/es\/dimensionamiento-de-baterias-solares-fuera-de-la-red\/\">gu\u00eda de dimensionamiento de bater\u00edas para sistemas aislados en regiones tropicales<\/a>. El cumplimiento del MPPT no demuestra que el sistema pueda soportar la carga nocturna o recuperarse despu\u00e9s de d\u00edas nublados.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Respuesta directa:<\/strong> Utilice la hoja de datos del m\u00f3dulo, las temperaturas de dise\u00f1o del sitio y el modelo exacto del inversor. Verifique la tensi\u00f3n m\u00e1xima, la tensi\u00f3n de operaci\u00f3n del MPPT, la corriente de cortocircuito y la potencia de entrada como l\u00edmites separados.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Fecha de revisi\u00f3n de la investigaci\u00f3n: 30 de septiembre de 2026. Las declaraciones cuantitativas est\u00e1n vinculadas a la fuente enlazada y deben verificarse nuevamente si la adquisici\u00f3n ocurre m\u00e1s tarde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para el contexto actual de mercado y pol\u00edticas, revisar <a href=\"https:\/\/pvwatts.nrel.gov\/\" target=\"_blank\" rel=\"noopener noreferrer\">Calculadora PVWatts del NREL<\/a>. PVWatts estima la producci\u00f3n de energ\u00eda fotovoltaica conectada a la red a partir de la ubicaci\u00f3n y las entradas del sistema. Es \u00fatil para el lado fotovoltaico de un estudio, pero no reemplaza el an\u00e1lisis de carga por intervalos y de cortes para el dimensionamiento de la bater\u00eda.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Calcule la tensi\u00f3n de circuito abierto en el caso m\u00e1s fr\u00edo<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para dise\u00f1adores fotovoltaicos residenciales y comerciales ligeros, la primera tarea es convertir el servicio previsto en entradas medibles y l\u00edmites de aceptaci\u00f3n. La siguiente tabla mantiene la decisi\u00f3n vinculada a la evidencia en lugar de a una etiqueta amplia de producto.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Verificaci\u00f3n<\/th><th>Entrada de c\u00e1lculo<\/th><th>Condici\u00f3n de aprobaci\u00f3n<\/th><\/tr><\/thead><tbody><tr><td>Tensi\u00f3n de circuito abierto en fr\u00edo<\/td><td>Voc del m\u00f3dulo y coeficiente de temperatura en fr\u00edo<\/td><td>La Voc de la cadena permanece por debajo del m\u00e1ximo absoluto<\/td><\/tr><tr><td>Tensi\u00f3n de operaci\u00f3n en caliente<\/td><td>Vmp del m\u00f3dulo y temperatura de celda en caliente<\/td><td>La Vmp de la cadena permanece dentro de la ventana del MPPT<\/td><\/tr><tr><td>Corriente del seguidor<\/td><td>Imp del m\u00f3dulo, cadenas en paralelo y margen bifacial cuando corresponda<\/td><td>No excede el l\u00edmite de corriente de operaci\u00f3n<\/td><\/tr><tr><td>Corriente de cortocircuito<\/td><td>Isc del m\u00f3dulo y factor de dise\u00f1o requerido<\/td><td>No excede el l\u00edmite de cortocircuito de entrada<\/td><\/tr><tr><td>Potencia del arreglo<\/td><td>N\u00famero de m\u00f3dulos y vatios nominales<\/td><td>Se ajusta al rango de dise\u00f1o CC\/CA aprobado<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Verificaciones de cadenas del MPPT<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-1024x1024.jpg\" alt=\"Dimensionamiento del MPPT del inversor h\u00edbrido: Kit de accesorios para soportes de montaje de inversor solar de 48V IP65 y conectores de cable impermeables escalados\" class=\"wp-image-2672\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-1024x1024.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-300x300.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-150x150.jpg 150w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-768x768.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-1536x1536.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-12x12.jpg 12w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-600x600.jpg 600w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-800x800.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-100x100.jpg 100w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Las mismas preguntas de evidencia y aceptaci\u00f3n pueden usarse al evaluar los <a href=\"https:\/\/hmxenergy.com\/es\/categoria-producto\/inversor-solar\/inversor-solar-ip65\/\">Inversores solares IP65<\/a>; de HMX; la informaci\u00f3n del cat\u00e1logo debe conciliarse con la cotizaci\u00f3n controlada y los planos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La comparaci\u00f3n t\u00e9cnica tambi\u00e9n debe verificarse contra <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/116482\" target=\"_blank\" rel=\"noopener noreferrer\">Alcance de seguridad de inversores IEC 62109-2<\/a>. IEC 62109-2 aborda los requisitos de seguridad para inversores fotovoltaicos, incluida la protecci\u00f3n contra peligros el\u00e9ctricos, t\u00e9rmicos, de incendio y mec\u00e1nicos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Errores de dise\u00f1o de cadenas que aparecen despu\u00e9s de la entrega de los m\u00f3dulos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Estas son las objeciones pr\u00e1cticas y los modos de falla con mayor probabilidad de detener una aprobaci\u00f3n, retrasar la puesta en marcha o generar una visita de servicio evitable para dise\u00f1adores fotovoltaicos residenciales y comerciales ligeros.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>La tensi\u00f3n de circuito abierto en fr\u00edo se verifica solo en condiciones de prueba est\u00e1ndar.<\/li><li>Las cadenas en paralelo exceden un l\u00edmite de corriente por seguidor aunque la corriente total del inversor parezca aceptable.<\/li><li>Los m\u00f3dulos sustitutos cambian los coeficientes de corriente o temperatura.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Preguntas que el comprador debe formular antes de la aprobaci\u00f3n<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00bfPermanece cada cadena dentro de la ventana del MPPT a temperatura de celda en caliente?<\/li><li>\u00bfSe verifican los l\u00edmites del seguidor por separado?<\/li><li>\u00bfQu\u00e9 revisiones de m\u00f3dulos est\u00e1n aprobadas para sustituci\u00f3n?<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Verifique la tensi\u00f3n y la corriente del m\u00f3dulo en caliente por MPPT<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La oferta comercial debe indicar sus supuestos, exclusiones y l\u00edmite de medici\u00f3n. Los compradores pueden entonces comparar sistemas sobre la misma base y mantener los cambios de dise\u00f1o posteriores bajo control documental.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Error com\u00fan<\/th><th>Por qu\u00e9 importa<\/th><th>Correcci\u00f3n<\/th><\/tr><\/thead><tbody><tr><td>Usar la temperatura media anual<\/td><td>Omite los extremos el\u00e9ctricos fr\u00edos y calientes<\/td><td>Use temperaturas de dise\u00f1o<\/td><\/tr><tr><td>Sumar las corrientes de los seguidores<\/td><td>Puede ocultar una sobrecarga por seguidor<\/td><td>Verifique cada seguidor por separado<\/td><\/tr><tr><td>Ignorar el reemplazo de m\u00f3dulos<\/td><td>Un m\u00f3dulo futuro puede tener una corriente diferente<\/td><td>Registre el conjunto de m\u00f3dulos aprobado<\/td><\/tr><tr><td>Asumir que el recorte es una falla<\/td><td>Cierto recorte puede ser intencional<\/td><td>Modelar los l\u00edmites anuales de energ\u00eda y t\u00e9rmicos<\/td><\/tr><tr><td>Mezclar orientaciones de cadenas en un mismo seguidor<\/td><td>Puede reducir la calidad del seguimiento<\/td><td>Agrupar cadenas compatibles<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Errores en la revisi\u00f3n de dise\u00f1o<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Puntos de acci\u00f3n para el equipo del proyecto<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Mantener una hoja de c\u00e1lculo con los n\u00fameros de revisi\u00f3n de m\u00f3dulos e inversores.<\/li><li>Mostrar la asignaci\u00f3n de cadenas en el diagrama unifilar.<\/li><li>Verificar las capacidades nominales de conectores, seccionadores y cables frente a la corriente y tensi\u00f3n de dise\u00f1o.<\/li><li>Poner en servicio cada cadena con verificaciones de polaridad, tensi\u00f3n y aislamiento.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para el trabajo de especificaci\u00f3n y aceptaci\u00f3n, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/2452\" target=\"_blank\" rel=\"noopener noreferrer\">C\u00f3digo IP IEC 60529<\/a> proporciona una referencia independiente. IEC 60529 es la referencia para las clasificaciones de protecci\u00f3n contra la penetraci\u00f3n en carcasas. Una clasificaci\u00f3n IP describe la protecci\u00f3n de la carcasa ensayada; no aprueba por s\u00ed sola un sitio de instalaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Mantener cada cadena dentro de los cuatro l\u00edmites el\u00e9ctricos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Calcular la tensi\u00f3n de circuito abierto en fr\u00edo utilizando el coeficiente de temperatura del m\u00f3dulo y el m\u00ednimo de dise\u00f1o del proyecto, no la temperatura media anual del aire. Calcular la tensi\u00f3n de operaci\u00f3n en caliente utilizando una suposici\u00f3n adecuada de temperatura de c\u00e9lula y confirmar que la cadena permanece dentro del rango MPPT. Registrar la ecuaci\u00f3n, las unidades y los datos de origen para que una sustituci\u00f3n de m\u00f3dulo pueda revisarse r\u00e1pidamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una referencia relacionada de HMX es la <a href=\"https:\/\/hmxenergy.com\/es\/producto\/inversor-solar-ip65-chmg055-16kw-48veu\/\">Inversor h\u00edbrido IP65 de 16kW<\/a>. Util\u00edcela para enmarcar la pr\u00f3xima conversaci\u00f3n con el proveedor, luego registre las desviaciones espec\u00edficas del proyecto antes de realizar el pedido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La corriente debe verificarse por seguidor y por entrada. A\u00f1adir la corriente de operaci\u00f3n de cadenas en paralelo y verificar la regla del inversor para corriente de cortocircuito y cualquier factor de dise\u00f1o requerido. La ganancia bifacial, las condiciones de alta irradiancia y las orientaciones desiguales pueden afectar la revisi\u00f3n. No combinar l\u00edmites de seguidores a menos que la hoja de datos describa expl\u00edcitamente hardware compartido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de la congelaci\u00f3n del dise\u00f1o, el equipo del proyecto debe revisar <a href=\"https:\/\/aseanenergy.org\/publications\/mapping-the-current-state-of-electrical-safety-regulations-in-asean-preliminary-assessment-of-electrical-safety-standards-and-practices-for-solar-photovoltaics-pv-and-battery-energy-storage-systems\/\" target=\"_blank\" rel=\"noopener noreferrer\">Evaluaci\u00f3n de seguridad el\u00e9ctrica de la ASEAN para PV y BESS<\/a>. El Centro de Energ\u00eda de la ASEAN encuentra una adopci\u00f3n y aplicaci\u00f3n desigual de las normas de seguridad de PV y BESS en toda la regi\u00f3n y recomienda una alineaci\u00f3n m\u00e1s estrecha con las normas internacionales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El programa final de cadenas debe indicar el n\u00famero de m\u00f3dulos, la orientaci\u00f3n, la asignaci\u00f3n al seguidor, y las capacidades nominales de cable, conector y seccionador. Durante la puesta en servicio, medir la polaridad y la tensi\u00f3n de circuito abierto por cadena e investigar diferencias inesperadas antes de la conexi\u00f3n. Conservar las revisiones aprobadas de m\u00f3dulos e inversores junto con la hoja de c\u00e1lculo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flujo de trabajo del proyecto<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Recopilar los coeficientes exactos del m\u00f3dulo y los l\u00edmites por seguidor del inversor.<\/li><li>Calcular Voc en fr\u00edo, Vmp en caliente, corriente de operaci\u00f3n y corriente de cortocircuito.<\/li><li>Asignar cada cadena a un seguidor en los planos de dise\u00f1o.<\/li><li>Verificar polaridad y tensi\u00f3n antes de energizar las entradas de CC.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Congelar las suposiciones de m\u00f3dulo e inversor<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilidad y la seguridad dependen del equipo tal como est\u00e1 instalado, no solo de una selecci\u00f3n de cat\u00e1logo. Conservar los identificadores de modelo y firmware, los planos de cableado y protecci\u00f3n, las distancias f\u00edsicas, los ajustes y las condiciones de prueba. El trabajo de servicio posterior debe comenzar desde esta l\u00ednea base y registrar cada cambio aprobado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Los compradores que definen el alcance inicial pueden comparar estos requisitos con los de HMX <a href=\"https:\/\/hmxenergy.com\/es\/guia-del-comprador-de-inversores-hibridos-solares\/\">Gu\u00eda del comprador de inversores h\u00edbridos<\/a>. La p\u00e1gina es una referencia de producto o proyecto; la idoneidad final a\u00fan requiere una especificaci\u00f3n de proyecto por escrito.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Equipos nombrados, firmware, accesorios, cables y ajustes de comunicaci\u00f3n.<\/li><li>Planos el\u00e9ctricos y f\u00edsicos de obra terminada con los puntos de aislamiento identificados.<\/li><li>Resultados de puesta en marcha para operaci\u00f3n normal, l\u00edmites y estados de fallo seleccionados.<\/li><li>Copias de seguridad, fotograf\u00edas, registro de cambios y un procedimiento de recuperaci\u00f3n para el t\u00e9cnico.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Despu\u00e9s de trabajos de servicio o firmware, comparar el sistema devuelto con la l\u00ednea base aprobada y repetir las pruebas afectadas. Esto agiliza la resoluci\u00f3n de problemas posterior y evita que un cambio de campo no documentado invalide una conclusi\u00f3n de compatibilidad o seguridad.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"427\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-1024x427.jpg\" alt=\"Dimensionamiento del MPPT del inversor h\u00edbrido: inversor solar h\u00edbrido IP21 IP65 ENERGY\" class=\"wp-image-3073\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-1024x427.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-300x125.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-768x320.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-1536x640.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-18x8.jpg 18w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-800x333.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Lista de verificaci\u00f3n de liberaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Liberar el equipo solo despu\u00e9s de que los c\u00e1lculos de dise\u00f1o, ajustes, planos y registros de prueba coincidan con la construcci\u00f3n f\u00edsica.<\/p>","protected":false},"excerpt":{"rendered":"<p>Dimensionar las cadenas fotovoltaicas para un inversor h\u00edbrido verificando la tensi\u00f3n de circuito abierto en fr\u00edo, la tensi\u00f3n de operaci\u00f3n en caliente, la corriente del MPPT y la relaci\u00f3n entre el arreglo y el inversor.<\/p>","protected":false},"author":4,"featured_media":2702,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3301","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"HMX ENERGY\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"HMX Energy Co., Ltd -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\" \/>\n\t\t<meta property=\"og:description\" content=\"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"740\" \/>\n\t\t<meta property=\"og:image:height\" content=\"495\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-04T08:22:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-04T00:50:08+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#blogposting\",\"name\":\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\",\"headline\":\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\",\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines.jpg\",\"width\":2400,\"height\":1824,\"caption\":\"Real-world installation case of hybrid solarinverter, residential villa solar storage project inPhilippines\"},\"datePublished\":\"2026-10-04T08:22:00+00:00\",\"dateModified\":\"2026-10-04T00:50:08+00:00\",\"inLanguage\":\"es-CL\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#webpage\"},\"articleSection\":\"Blog&amp;News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog&amp;News\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#listItem\",\"name\":\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#listItem\",\"position\":3,\"name\":\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#organization\",\"name\":\"HMX Energy Co., Ltd\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/\",\"telephone\":\"+8613310869219\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/HM-logo.png\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#organizationLogo\",\"width\":740,\"height\":495,\"caption\":\"HM logo\"},\"image\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/people\\\/Huiming-green-ennergy\\\/100091938723333\\\/\",\"https:\\\/\\\/www.instagram.com\\\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/shenzhen-hmx-new-energy-co-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/\",\"name\":\"HMX ENERGY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#webpage\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/\",\"name\":\"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\",\"description\":\"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.\",\"inLanguage\":\"es-CL\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/author\\\/hmxenergy\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines.jpg\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#mainImage\",\"width\":2400,\"height\":1824,\"caption\":\"Real-world installation case of hybrid solarinverter, residential villa solar storage project inPhilippines\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/hybrid-inverter-mppt-sizing\\\/#mainImage\"},\"datePublished\":\"2026-10-04T08:22:00+00:00\",\"dateModified\":\"2026-10-04T00:50:08+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/\",\"name\":\"HMX Energy Co., Ltd\",\"inLanguage\":\"es-CL\",\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Dimensionamiento del MPPT del inversor h\u00edbrido: Voc en fr\u00edo, Vmp en caliente y corriente","description":"Verificar el dimensionamiento del MPPT del inversor h\u00edbrido con la tensi\u00f3n de circuito abierto en clima fr\u00edo, la tensi\u00f3n de operaci\u00f3n del m\u00f3dulo en caliente, la corriente de entrada y la asignaci\u00f3n del seguidor.","canonical_url":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#blogposting","name":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","headline":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","author":{"@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author"},"publisher":{"@id":"https:\/\/hmxenergy.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines.jpg","width":2400,"height":1824,"caption":"Real-world installation case of hybrid solarinverter, residential villa solar storage project inPhilippines"},"datePublished":"2026-10-04T08:22:00+00:00","dateModified":"2026-10-04T00:50:08+00:00","inLanguage":"es-CL","mainEntityOfPage":{"@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#webpage"},"isPartOf":{"@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#webpage"},"articleSection":"Blog&amp;News"},{"@type":"BreadcrumbList","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/hmxenergy.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/category\/blog\/#listItem","name":"Blog&amp;News"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/category\/blog\/#listItem","position":2,"name":"Blog&amp;News","item":"https:\/\/hmxenergy.com\/es\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#listItem","name":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current"},"previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#listItem","position":3,"name":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/es\/category\/blog\/#listItem","name":"Blog&amp;News"}}]},{"@type":"Organization","@id":"https:\/\/hmxenergy.com\/es\/#organization","name":"HMX Energy Co., Ltd","url":"https:\/\/hmxenergy.com\/es\/","telephone":"+8613310869219","logo":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#organizationLogo","width":740,"height":495,"caption":"HM logo"},"image":{"@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","https:\/\/www.instagram.com\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr","https:\/\/www.linkedin.com\/company\/shenzhen-hmx-new-energy-co-ltd\/"]},{"@type":"Person","@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author","url":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/","name":"HMX ENERGY"},{"@type":"WebPage","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#webpage","url":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/","name":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","description":"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.","inLanguage":"es-CL","isPartOf":{"@id":"https:\/\/hmxenergy.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#breadcrumblist"},"author":{"@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author"},"creator":{"@id":"https:\/\/hmxenergy.com\/es\/author\/hmxenergy\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Real-world-installation-case-of-hybrid-solarinverter-residential-villa-solar-storage-project-inPhilippines.jpg","@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#mainImage","width":2400,"height":1824,"caption":"Real-world installation case of hybrid solarinverter, residential villa solar storage project inPhilippines"},"primaryImageOfPage":{"@id":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/#mainImage"},"datePublished":"2026-10-04T08:22:00+00:00","dateModified":"2026-10-04T00:50:08+00:00"},{"@type":"WebSite","@id":"https:\/\/hmxenergy.com\/es\/#website","url":"https:\/\/hmxenergy.com\/es\/","name":"HMX Energy Co., Ltd","inLanguage":"es-CL","publisher":{"@id":"https:\/\/hmxenergy.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"HMX Energy Co., Ltd -","og:type":"article","og:title":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","og:description":"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.","og:url":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/","og:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:secure_url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:width":740,"og:image:height":495,"article:published_time":"2026-10-04T08:22:00+00:00","article:modified_time":"2026-10-04T00:50:08+00:00","article:publisher":"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","twitter:card":"summary_large_image","twitter:title":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","twitter:description":"Check hybrid inverter MPPT sizing with cold-weather open-circuit voltage, hot-module operating voltage, input current and tracker allocation.","twitter:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png"},"aioseo_meta_data":{"post_id":"3301","title":"Dimensionamiento del MPPT del inversor h\u00edbrido: Voc en fr\u00edo, Vmp en caliente y corriente","description":"Verificar el dimensionamiento del MPPT del inversor h\u00edbrido con la tensi\u00f3n de circuito abierto en clima fr\u00edo, la tensi\u00f3n de operaci\u00f3n del m\u00f3dulo en caliente, la corriente de entrada y la asignaci\u00f3n del seguidor.","keywords":null,"keyphrases":{"focus":{"keyphrase":"hybrid inverter MPPT sizing","score":0,"analysis":[]},"additional":[]},"focus_keyword":"hybrid inverter MPPT sizing","additional_keywords":null,"truseo_locale":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-30 03:33:50","updated":"2026-10-04 10:23:01"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/es\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/es\/category\/blog\/\" title=\"Blog&amp;News\">Blog&amp;News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tHybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/hmxenergy.com\/es\/"},{"label":"Blog&amp;News","link":"https:\/\/hmxenergy.com\/es\/category\/blog\/"},{"label":"Hybrid Inverter MPPT Sizing: Cold Voc, Hot Vmp and Current","link":"https:\/\/hmxenergy.com\/es\/hybrid-inverter-mppt-sizing\/"}],"_links":{"self":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts\/3301","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/comments?post=3301"}],"version-history":[{"count":6,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts\/3301\/revisions"}],"predecessor-version":[{"id":3478,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/posts\/3301\/revisions\/3478"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/media\/2702"}],"wp:attachment":[{"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/media?parent=3301"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/categories?post=3301"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hmxenergy.com\/es\/wp-json\/wp\/v2\/tags?post=3301"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}