{"id":3299,"date":"2026-10-04T02:14:00","date_gmt":"2026-10-04T02:14:00","guid":{"rendered":"https:\/\/hmxenergy.com\/?p=3299"},"modified":"2026-10-04T00:50:06","modified_gmt":"2026-10-04T00:50:06","slug":"onduleur-solaire-ip21-vs-ip65","status":"publish","type":"post","link":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/","title":{"rendered":"Onduleurs solaires IP21 vs IP65 : La limite d'installation"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"427\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-1024x427.jpg\" alt=\"Onduleur solaire IP21 vs IP65 : onduleur solaire hybride IP21 IP65 \u00c9NERGIE\" class=\"wp-image-3073\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-1024x427.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-300x125.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-768x320.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-1536x640.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-18x8.jpg 18w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY-800x333.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Un indice IP d\u00e9crit la protection de l'enveloppe dans le cadre d'essais d\u00e9finis. Il ne certifie pas qu'un onduleur peut \u00eatre install\u00e9 n'importe o\u00f9 sans abri, drainage, contr\u00f4le de temp\u00e9rature ou ma\u00eetrise des entr\u00e9es de c\u00e2bles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les acheteurs, la question utile n'est pas simplement \u201c IP21 ou IP65 ? \u201d. Il s'agit de savoir si l'enveloppe s\u00e9lectionn\u00e9e et la m\u00e9thode d'installation correspondent \u00e0 l'exposition r\u00e9elle et aux instructions du fabricant.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un examen concret au niveau de l'\u00e9quipement, appliquez les v\u00e9rifications ci-dessus au <a href=\"https:\/\/hmxenergy.com\/fr\/categorie-produit\/onduleur-solaire\/\">gamme d'onduleurs solaires<\/a> et demandez confirmation pour les conditions du site et le mode d'exploitation pr\u00e9vus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pourquoi une \u00e9tiquette IP ne suffit pas \u00e0 d\u00e9terminer la conception du site<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il s'agit des objections pratiques et des modes de d\u00e9faillance les plus susceptibles de bloquer une approbation, de retarder la mise en service ou de g\u00e9n\u00e9rer un appel de service \u00e9vitable pour les distributeurs solaires et les installateurs EPC.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Les presse-\u00e9toupes, les ouvertures ou les modifications sur site peuvent invalider la protection de l'enveloppe.<\/li><li>Le soleil direct, le sel, les insectes, la condensation et les inondations ne sont pas d\u00e9finis par IP65 seul.<\/li><li>L'\u00e9quipement int\u00e9rieur est install\u00e9 dans une pi\u00e8ce avec une \u00e9vacuation de chaleur inad\u00e9quate.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Questions que l'acheteur doit poser avant l'approbation<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Quelle enveloppe exacte a \u00e9t\u00e9 test\u00e9e et avec quels accessoires ?<\/li><li>Quelles expositions environnementales existent \u00e0 la position de montage ?<\/li><li>Comment la chaleur, le drainage et l'acc\u00e8s pour la maintenance seront-ils g\u00e9r\u00e9s ?<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La s\u00e9lection de l'enveloppe suit la m\u00eame logique ax\u00e9e sur le site utilis\u00e9e dans le <a href=\"https:\/\/hmxenergy.com\/fr\/batterie-murale-vs-batterie-au-sol\/\">guide d'installation de batteries murales ou au sol<\/a>: la surface de montage, les d\u00e9gagements, le cheminement de l'eau et l'acc\u00e8s pour l'entretien doivent \u00eatre d\u00e9finis avant la s\u00e9lection de l'\u00e9quipement.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>R\u00e9ponse directe :<\/strong> Classifiez l'emplacement de montage avant de s\u00e9lectionner le produit. Enregistrez la pluie directe, les projections pouss\u00e9es par le vent, la poussi\u00e8re, les insectes, la condensation, la lumi\u00e8re du soleil, la temp\u00e9rature ambiante et l'acc\u00e8s pour l'entretien.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Date de r\u00e9vision de la recherche : 30 septembre 2026. Les affirmations quantitatives sont li\u00e9es \u00e0 la source cit\u00e9e et doivent \u00eatre rev\u00e9rifi\u00e9es si l'approvisionnement intervient plus tard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les travaux de sp\u00e9cification et d'acceptation, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/2452\" target=\"_blank\" rel=\"noopener noreferrer\">Code IP CEI 60529<\/a> fournit une r\u00e9f\u00e9rence ind\u00e9pendante. La CEI 60529 est la r\u00e9f\u00e9rence pour les classifications de protection contre la p\u00e9n\u00e9tration des enveloppes. Un indice IP d\u00e9crit la protection test\u00e9e de l'enveloppe ; il n'approuve pas \u00e0 lui seul un site d'installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Commencez par l'environnement d'installation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les distributeurs solaires et les installateurs EPC, la premi\u00e8re t\u00e2che consiste \u00e0 transformer le service pr\u00e9vu en donn\u00e9es mesurables et en limites d'acceptation. Le tableau suivant maintient la d\u00e9cision li\u00e9e aux preuves plut\u00f4t qu'\u00e0 une large \u00e9tiquette produit.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u00c9l\u00e9ment<\/th><th>Vue de planification IP21<\/th><th>Vue de planification IP65<\/th><\/tr><\/thead><tbody><tr><td>Approche typique de l'emplacement<\/td><td>Int\u00e9rieur prot\u00e9g\u00e9 ou enveloppe appropri\u00e9e<\/td><td>Protection accrue contre la poussi\u00e8re et les jets d'eau<\/td><\/tr><tr><td>Intemp\u00e9ries directes<\/td><td>\u00c0 \u00e9viter sauf si une protection approuv\u00e9e est fournie<\/td><td>Toujours suivre les instructions de montage et relatives aux intemp\u00e9ries<\/td><\/tr><tr><td>Entr\u00e9es de c\u00e2bles<\/td><td>Maintenir la protection requise de l'enveloppe<\/td><td>Des presse-\u00e9toupes et une \u00e9tanch\u00e9it\u00e9 corrects sont essentiels<\/td><\/tr><tr><td>\u00c9vacuation de la chaleur<\/td><td>La ventilation de la pi\u00e8ce peut \u00eatre importante<\/td><td>Le gain solaire et la temp\u00e9rature ambiante ext\u00e9rieure peuvent \u00eatre importants<\/td><\/tr><tr><td>Maintenance<\/td><td>Garder les \u00e9vents et la pi\u00e8ce propres<\/td><td>Inspecter les joints, les presse-\u00e9toupes et les chemins thermiques<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Questions d'installation par classe d'enveloppe<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-1024x1024.jpg\" alt=\"Onduleur solaire IP21 vs IP65 : kit d&#039;accessoires pour onduleur solaire 48 V IP65, supports de montage et connecteurs de c\u00e2bles \u00e9tanches, redimensionn\u00e9\" class=\"wp-image-2672\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-1024x1024.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-300x300.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-150x150.jpg 150w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-768x768.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-1536x1536.jpg 1536w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-12x12.jpg 12w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-600x600.jpg 600w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-800x800.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1-100x100.jpg 100w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Accessory-kit-for-IP65-48V-solar-inverter-mounting-brackets-and-waterproof-cable-connectors-scaled-1.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Les m\u00eames questions de preuve et d'acceptation peuvent \u00eatre utilis\u00e9es lors de l'\u00e9valuation du projet de stockage d'HMX <a href=\"https:\/\/hmxenergy.com\/fr\/categorie-produit\/onduleur-solaire\/onduleur-solaire-ip21\/\">Onduleurs solaires IP21<\/a>; les informations du catalogue doivent \u00eatre reconcili\u00e9es avec la quotation contr\u00f4l\u00e9e et les dessins.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avant le gel de la conception, l'\u00e9quipe projet doit examiner <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/116482\" target=\"_blank\" rel=\"noopener noreferrer\">Port\u00e9e de s\u00e9curit\u00e9 des onduleurs IEC 62109-2<\/a>. La CEI 62109-2 traite des exigences de s\u00e9curit\u00e9 pour les onduleurs photovolta\u00efques, y compris la protection contre les risques \u00e9lectriques, thermiques, d'incendie et m\u00e9caniques.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Faire correspondre la protection de l'enveloppe avec le montage et l'entr\u00e9e de c\u00e2bles<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'offre commerciale doit indiquer ses hypoth\u00e8ses, exclusions et p\u00e9rim\u00e8tre de mesure. Les acheteurs peuvent alors comparer les syst\u00e8mes sur la m\u00eame base et maintenir les modifications de conception ult\u00e9rieures sous contr\u00f4le documentaire.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Observation du site<\/th><th>Risque<\/th><th>R\u00e9ponse de conception<\/th><\/tr><\/thead><tbody><tr><td>Soleil direct<\/td><td>Temp\u00e9rature interne plus \u00e9lev\u00e9e<\/td><td>Ombrager lorsque cela est permis et v\u00e9rifier le d\u00e9classement<\/td><\/tr><tr><td>Air salin ou industriel<\/td><td>Corrosion<\/td><td>Confirmer le mat\u00e9riau et la protection contre la corrosion<\/td><\/tr><tr><td>Mur expos\u00e9 aux inondations<\/td><td>Exposition \u00e0 l'eau par le bas<\/td><td>Sur\u00e9lever ou d\u00e9placer l'\u00e9quipement<\/td><\/tr><tr><td>Atelier poussi\u00e9reux<\/td><td>Chemins thermiques obstru\u00e9s<\/td><td>Plan de nettoyage et enceinte adapt\u00e9e<\/td><\/tr><tr><td>Armoire \u00e9troite<\/td><td>Accumulation de chaleur et acc\u00e8s difficile<\/td><td>Pr\u00e9voir un d\u00e9gagement et une ventilation<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">De l'\u00e9tude de site \u00e0 la s\u00e9lection de l'onduleur<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Points d'action pour l'\u00e9quipe projet<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>V\u00e9rifier l'indice IP exact sur la fiche technique du mod\u00e8le et sur la plaque signal\u00e9tique.<\/li><li>Utiliser des presse-\u00e9toupes, des bouchons pour entr\u00e9es inutilis\u00e9es et des m\u00e9thodes de conduit qui pr\u00e9servent la protection de l'enceinte.<\/li><li>V\u00e9rifier le d\u00e9classement thermique \u00e0 la position d'installation.<\/li><li>Ne pas pr\u00e9senter l'IP65 comme une preuve de submersion, de r\u00e9sistance aux inondations ou de dur\u00e9e de vie ext\u00e9rieure illimit\u00e9e.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour l'examen final des preuves, utiliser <a href=\"https:\/\/pvwatts.nrel.gov\/\" target=\"_blank\" rel=\"noopener noreferrer\">Calculateur PVWatts du NREL<\/a> comme source de v\u00e9rification. PVWatts estime la production d'\u00e9nergie photovolta\u00efque raccord\u00e9e au r\u00e9seau \u00e0 partir de la localisation et des param\u00e8tres du syst\u00e8me. Il est utile pour le volet photovolta\u00efque d'une \u00e9tude, mais il ne remplace pas l'analyse des intervalles de charge et des coupures pour le dimensionnement de la batterie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Traduire l'indice de l'enceinte en une \u00e9valuation compl\u00e8te du site<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Examiner l'enceinte test\u00e9e, l'orientation et les accessoires nomm\u00e9s par le fabricant. Les trous perc\u00e9s sur site, les presse-\u00e9toupes inadapt\u00e9s, les conduits ouverts ou les joints endommag\u00e9s peuvent modifier la protection obtenue apr\u00e8s l'installation. Les entr\u00e9es de c\u00e2bles doivent \u00eatre s\u00e9lectionn\u00e9es et install\u00e9es en fonction de la section des conducteurs, du mat\u00e9riau de l'enceinte et de l'exposition, avec les ouvertures inutilis\u00e9es correctement obtur\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une r\u00e9f\u00e9rence HMX associ\u00e9e est la <a href=\"https:\/\/hmxenergy.com\/fr\/categorie-produit\/onduleur-solaire\/onduleur-solaire-ip65\/\">Onduleurs solaires IP65<\/a>. Utilisez-la pour encadrer la prochaine discussion avec le fournisseur, puis consignez les \u00e9carts sp\u00e9cifiques au projet avant de commander.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'aptitude \u00e0 l'ext\u00e9rieur d\u00e9pend \u00e9galement de l'exposition aux ultraviolets, du chauffage solaire direct, de la condensation, de l'atmosph\u00e8re corrosive, des insectes, du drainage, des inondations et des impacts m\u00e9caniques. L'aptitude \u00e0 l'int\u00e9rieur d\u00e9pend de la temp\u00e9rature ambiante, de la ventilation et de la gestion de la poussi\u00e8re. Ces facteurs doivent \u00eatre consign\u00e9s s\u00e9par\u00e9ment au lieu d'\u00eatre r\u00e9duits \u00e0 un seul choix IP21 ou IP65.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour le contexte actuel du march\u00e9 et des politiques, consultez <a href=\"https:\/\/aseanenergy.org\/publications\/mapping-the-current-state-of-electrical-safety-regulations-in-asean-preliminary-assessment-of-electrical-safety-standards-and-practices-for-solar-photovoltaics-pv-and-battery-energy-storage-systems\/\" target=\"_blank\" rel=\"noopener noreferrer\">\u00c9valuation de la s\u00e9curit\u00e9 \u00e9lectrique de l'ASEAN pour le PV et les BESS<\/a>. Le Centre de l'\u00e9nergie de l'ASEAN constate une adoption et une application in\u00e9gales des normes de s\u00e9curit\u00e9 pour le PV et les BESS dans la r\u00e9gion et recommande un alignement plus \u00e9troit avec les normes internationales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La mise en service doit inclure l'inspection de l'enceinte, le couple de serrage des presse-\u00e9toupes lorsque sp\u00e9cifi\u00e9, les v\u00e9rifications de mise \u00e0 la terre de protection, le d\u00e9gagement pour la circulation d'air et des photographies des entr\u00e9es r\u00e9alis\u00e9es. Les instructions de maintenance doivent pr\u00e9ciser comment les joints, les filtres, les ventilateurs et la corrosion sont inspect\u00e9s. Toute m\u00e9thode de nettoyage doit rester compatible avec l'enceinte et les consignes de s\u00e9curit\u00e9 \u00e9lectrique.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flux de travail du projet<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Confirmer l'indice et les conditions d'installation pour le mod\u00e8le exact.<\/li><li>\u00c9valuer l'exposition \u00e0 la chaleur, \u00e0 l'eau, \u00e0 la poussi\u00e8re, au sel, au soleil et aux impacts.<\/li><li>Approuver les entr\u00e9es, les d\u00e9gagements, le drainage et les d\u00e9tails de ventilation.<\/li><li>Inspecter l'int\u00e9grit\u00e9 de l'enceinte lors de la mise en service et de la maintenance planifi\u00e9e.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Consigner la limite IP install\u00e9e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilit\u00e9 et la s\u00e9curit\u00e9 d\u00e9pendent de l'\u00e9quipement tel qu'install\u00e9, et non seulement d'un choix de catalogue. Conserver les identifiants de mod\u00e8le et de firmware, les sch\u00e9mas de c\u00e2blage et de protection, les d\u00e9gagements physiques, les param\u00e8tres et les conditions d'essai. Les interventions de service ult\u00e9rieures doivent partir de cette r\u00e9f\u00e9rence et enregistrer chaque modification approuv\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les acheteurs d\u00e9finissant le p\u00e9rim\u00e8tre initial peuvent comparer ces exigences avec la <a href=\"https:\/\/hmxenergy.com\/fr\/produit\/onduleur-solaire-ip65-chmg055-16kw-48veu\/\">Onduleur hybride IP65 de 16 kW<\/a>. La page est une r\u00e9f\u00e9rence produit ou projet ; l'ad\u00e9quation finale n\u00e9cessite toujours une sp\u00e9cification de projet \u00e9crite.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00c9quipements, firmwares, accessoires, c\u00e2bles et param\u00e8tres de communication nomm\u00e9s.<\/li><li>Sch\u00e9mas \u00e9lectriques et physiques tels que construits, avec points d'isolement identifi\u00e9s.<\/li><li>R\u00e9sultats de mise en service pour le fonctionnement normal, les limites et les \u00e9tats de d\u00e9faillance s\u00e9lectionn\u00e9s.<\/li><li>Sauvegardes, photographies, journal des modifications et proc\u00e9dure de r\u00e9cup\u00e9ration pour technicien.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Apr\u00e8s une intervention de service ou sur le firmware, comparer le syst\u00e8me retourn\u00e9 \u00e0 la r\u00e9f\u00e9rence approuv\u00e9e et r\u00e9p\u00e9ter les tests concern\u00e9s. Cela acc\u00e9l\u00e8re le d\u00e9pannage ult\u00e9rieur et \u00e9vite qu'une modification terrain non document\u00e9e n'invalide une conclusion de compatibilit\u00e9 ou de s\u00e9curit\u00e9.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"756\" height=\"756\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter-.jpg\" alt=\"Onduleur solaire IP21 vs IP65 : onduleur hybride 48 V 6,5 kW 12 kW\" class=\"wp-image-2557\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter-.jpg 756w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter--300x300.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter--150x150.jpg 150w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter--12x12.jpg 12w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter--600x600.jpg 600w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/1-48v-6.5kw-12kw-hybrid-inverter--100x100.jpg 100w\" sizes=\"(max-width: 756px) 100vw, 756px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">All\u00e9gation \u00e0 \u00e9viter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9viter d'affirmer qu'un seul indice ou certificat r\u00e9pond \u00e0 toutes les questions d'installation. Pr\u00e9ciser la port\u00e9e test\u00e9e et les v\u00e9rifications restantes du projet.<\/p>","protected":false},"excerpt":{"rendered":"<p>Comparez les onduleurs solaires IP21 et IP65 selon l'IEC 60529, puis \u00e9valuez l'emplacement, la pluie, la poussi\u00e8re, la chaleur, l'entr\u00e9e des c\u00e2bles et les besoins de maintenance.<\/p>","protected":false},"author":4,"featured_media":3073,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3299","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"HMX ENERGY\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"HMX Energy Co., Ltd -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"IP21 vs IP65 Solar Inverters: The Installation Boundary\" \/>\n\t\t<meta property=\"og:description\" content=\"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"740\" \/>\n\t\t<meta property=\"og:image:height\" content=\"495\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-04T02:14:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-04T00:50:06+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"IP21 vs IP65 Solar Inverters: The Installation Boundary\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#blogposting\",\"name\":\"IP21 vs IP65 Solar Inverters: The Installation Boundary\",\"headline\":\"IP21 vs IP65 Solar Inverters: The Installation Boundary\",\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hybrid-solar-inverter-IP21-IP65-ENERGY.jpg\",\"width\":1920,\"height\":800,\"caption\":\"hybrid solar inverter IP21 IP65 ENERGY\"},\"datePublished\":\"2026-10-04T02:14:00+00:00\",\"dateModified\":\"2026-10-04T00:50:06+00:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#webpage\"},\"articleSection\":\"Blog&amp;News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog&amp;News\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#listItem\",\"name\":\"IP21 vs IP65 Solar Inverters: The Installation Boundary\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#listItem\",\"position\":3,\"name\":\"IP21 vs IP65 Solar Inverters: The Installation Boundary\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#organization\",\"name\":\"HMX Energy Co., Ltd\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/\",\"telephone\":\"+8613310869219\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/HM-logo.png\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#organizationLogo\",\"width\":740,\"height\":495,\"caption\":\"HM logo\"},\"image\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/people\\\/Huiming-green-ennergy\\\/100091938723333\\\/\",\"https:\\\/\\\/www.instagram.com\\\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/shenzhen-hmx-new-energy-co-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/\",\"name\":\"HMX ENERGY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#webpage\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/\",\"name\":\"IP21 vs IP65 Solar Inverters: The Installation Boundary\",\"description\":\"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hybrid-solar-inverter-IP21-IP65-ENERGY.jpg\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#mainImage\",\"width\":1920,\"height\":800,\"caption\":\"hybrid solar inverter IP21 IP65 ENERGY\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/ip21-vs-ip65-solar-inverter\\\/#mainImage\"},\"datePublished\":\"2026-10-04T02:14:00+00:00\",\"dateModified\":\"2026-10-04T00:50:06+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/\",\"name\":\"HMX Energy Co., Ltd\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Onduleurs solaires IP21 vs IP65 : La limite d'installation","description":"Utilisez correctement les indices de protection IP21 et IP65 en v\u00e9rifiant le montage, l'abri, le drainage, les entr\u00e9es de c\u00e2bles, la temp\u00e9rature, la condensation, la corrosion et l'acc\u00e8s pour la maintenance.","canonical_url":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#blogposting","name":"IP21 vs IP65 Solar Inverters: The Installation Boundary","headline":"IP21 vs IP65 Solar Inverters: The Installation Boundary","author":{"@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author"},"publisher":{"@id":"https:\/\/hmxenergy.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY.jpg","width":1920,"height":800,"caption":"hybrid solar inverter IP21 IP65 ENERGY"},"datePublished":"2026-10-04T02:14:00+00:00","dateModified":"2026-10-04T00:50:06+00:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#webpage"},"isPartOf":{"@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#webpage"},"articleSection":"Blog&amp;News"},{"@type":"BreadcrumbList","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/hmxenergy.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/category\/blog\/#listItem","name":"Blog&amp;News"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/category\/blog\/#listItem","position":2,"name":"Blog&amp;News","item":"https:\/\/hmxenergy.com\/fr\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#listItem","name":"IP21 vs IP65 Solar Inverters: The Installation Boundary"},"previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#listItem","position":3,"name":"IP21 vs IP65 Solar Inverters: The Installation Boundary","previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/category\/blog\/#listItem","name":"Blog&amp;News"}}]},{"@type":"Organization","@id":"https:\/\/hmxenergy.com\/fr\/#organization","name":"HMX Energy Co., Ltd","url":"https:\/\/hmxenergy.com\/fr\/","telephone":"+8613310869219","logo":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#organizationLogo","width":740,"height":495,"caption":"HM logo"},"image":{"@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","https:\/\/www.instagram.com\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr","https:\/\/www.linkedin.com\/company\/shenzhen-hmx-new-energy-co-ltd\/"]},{"@type":"Person","@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author","url":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/","name":"HMX ENERGY"},{"@type":"WebPage","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#webpage","url":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/","name":"IP21 vs IP65 Solar Inverters: The Installation Boundary","description":"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/hmxenergy.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#breadcrumblist"},"author":{"@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author"},"creator":{"@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/hybrid-solar-inverter-IP21-IP65-ENERGY.jpg","@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#mainImage","width":1920,"height":800,"caption":"hybrid solar inverter IP21 IP65 ENERGY"},"primaryImageOfPage":{"@id":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/#mainImage"},"datePublished":"2026-10-04T02:14:00+00:00","dateModified":"2026-10-04T00:50:06+00:00"},{"@type":"WebSite","@id":"https:\/\/hmxenergy.com\/fr\/#website","url":"https:\/\/hmxenergy.com\/fr\/","name":"HMX Energy Co., Ltd","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/hmxenergy.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"HMX Energy Co., Ltd -","og:type":"article","og:title":"IP21 vs IP65 Solar Inverters: The Installation Boundary","og:description":"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.","og:url":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/","og:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:secure_url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:width":740,"og:image:height":495,"article:published_time":"2026-10-04T02:14:00+00:00","article:modified_time":"2026-10-04T00:50:06+00:00","article:publisher":"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","twitter:card":"summary_large_image","twitter:title":"IP21 vs IP65 Solar Inverters: The Installation Boundary","twitter:description":"Use IP21 and IP65 ratings correctly by checking mounting, shelter, drainage, cable entries, temperature, condensation, corrosion and service access.","twitter:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png"},"aioseo_meta_data":{"post_id":"3299","title":"Onduleurs solaires IP21 vs IP65 : La limite d'installation","description":"Utilisez correctement les indices de protection IP21 et IP65 en v\u00e9rifiant le montage, l'abri, le drainage, les entr\u00e9es de c\u00e2bles, la temp\u00e9rature, la condensation, la corrosion et l'acc\u00e8s pour la maintenance.","keywords":null,"keyphrases":{"focus":{"keyphrase":"IP21 vs IP65 solar inverter","score":0,"analysis":[]},"additional":[]},"focus_keyword":"IP21 vs IP65 solar inverter","additional_keywords":null,"truseo_locale":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-30 03:33:46","updated":"2026-10-04 03:52:25"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/fr\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/fr\/category\/blog\/\" title=\"Blog&amp;News\">Blog&amp;News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tIP21 vs IP65 Solar Inverters: The Installation Boundary\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/hmxenergy.com\/fr\/"},{"label":"Blog&amp;News","link":"https:\/\/hmxenergy.com\/fr\/category\/blog\/"},{"label":"IP21 vs IP65 Solar Inverters: The Installation Boundary","link":"https:\/\/hmxenergy.com\/fr\/ip21-vs-ip65-solar-inverter\/"}],"_links":{"self":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts\/3299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/comments?post=3299"}],"version-history":[{"count":6,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts\/3299\/revisions"}],"predecessor-version":[{"id":3477,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts\/3299\/revisions\/3477"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/media\/3073"}],"wp:attachment":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/media?parent=3299"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/categories?post=3299"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/tags?post=3299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}