{"id":3303,"date":"2026-10-04T14:05:00","date_gmt":"2026-10-04T14:05:00","guid":{"rendered":"https:\/\/hmxenergy.com\/?p=3303"},"modified":"2026-10-04T00:50:09","modified_gmt":"2026-10-04T00:50:09","slug":"onduleur-de-batterie-can-vs-rs485","status":"publish","type":"post","link":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/","title":{"rendered":"Liaisons de batterie CAN vs RS485 : ce que les installateurs doivent mettre en service"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"753\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank.jpg\" alt=\"Communication onduleur-batterie CAN vs RS485 : photo r\u00e9elle du c\u00e2blage terrain d&#039;un onduleur solaire 48V IP65 connect\u00e9 \u00e0 un parc de batteries LiFePO4\" class=\"wp-image-2614\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank-300x282.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank-768x723.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank-13x12.jpg 13w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">CAN et RS485 d\u00e9crivent des technologies de communication ; ils ne garantissent pas que deux produits comprennent le m\u00eame protocole de batterie. La compatibilit\u00e9 \u00e9lectrique, le brochage des connecteurs, les d\u00e9finitions de messages, le d\u00e9bit en bauds, l'adressage et le micrologiciel doivent tous correspondre.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un distributeur, l'all\u00e9gation de compatibilit\u00e9 la plus s\u00fbre est une combinaison test\u00e9e de mod\u00e8les et de versions de micrologiciel nomm\u00e9s, \u00e9tay\u00e9e par un sch\u00e9ma de c\u00e2blage et un r\u00e9sultat de fonctionnement d\u00e9fini.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une r\u00e9f\u00e9rence HMX associ\u00e9e est la <a href=\"https:\/\/hmxenergy.com\/fr\/produit\/batterie-de-stockage-denergie-domestique-lifepo4-murale-de-512-v-200-ah-10-kwh\/\">Batterie LiFePO4 murale de 10 kWh<\/a>. Utilisez-la pour encadrer la prochaine discussion avec le fournisseur, puis consignez les \u00e9carts sp\u00e9cifiques au projet avant de commander.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La mise en service de la communication devient plus claire lorsque la propri\u00e9t\u00e9 des signaux est d\u00e9finie en premier. Le <a href=\"https:\/\/hmxenergy.com\/fr\/bms-pcs-ems-bess\/\">guide d'interface BMS, PCS et EMS<\/a> montre comment attribuer les responsabilit\u00e9s de commande, de limite, d'alarme et de repli avant de tester la liaison physique.<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>R\u00e9ponse directe :<\/strong> Demandez une matrice de compatibilit\u00e9 et un enregistrement de test. Ne pr\u00e9sumez pas de la prise en charge parce que les deux produits mentionnent CAN, RS485 ou le nom d'un protocole tiers.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Date de r\u00e9vision de la recherche : 30 septembre 2026. Les affirmations quantitatives sont li\u00e9es \u00e0 la source cit\u00e9e et doivent \u00eatre rev\u00e9rifi\u00e9es si l'approvisionnement intervient plus tard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La comparaison technique doit \u00e9galement \u00eatre v\u00e9rifi\u00e9e par rapport \u00e0 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/64073\" target=\"_blank\" rel=\"noopener noreferrer\">Champ d'application de l'IEC 62619:2022<\/a>. L'IEC 62619:2022 couvre les exigences de s\u00e9curit\u00e9 et les essais pour les cellules et batteries secondaires au lithium utilis\u00e9es dans des applications industrielles, y compris les usages stationnaires et mobiles.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">S\u00e9parer la couche physique du protocole de batterie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les distributeurs de batteries, les installateurs d'onduleurs et les int\u00e9grateurs de syst\u00e8mes, la premi\u00e8re t\u00e2che consiste \u00e0 transformer le service pr\u00e9vu en entr\u00e9es mesurables et en limites d'acceptation. Le tableau suivant maintient la d\u00e9cision li\u00e9e \u00e0 des preuves plut\u00f4t qu'\u00e0 une large \u00e9tiquette produit.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Couche<\/th><th>V\u00e9rification CAN<\/th><th>V\u00e9rification RS485<\/th><\/tr><\/thead><tbody><tr><td>Connexion physique<\/td><td>Connecteur et broches CAN-H\/CAN-L<\/td><td>Connecteur et polarit\u00e9 A\/B<\/td><\/tr><tr><td>Configuration du r\u00e9seau<\/td><td>R\u00e8gles de terminaison et de n\u0153uds<\/td><td>Terminaison, polarisation et adresse<\/td><\/tr><tr><td>Liaison de donn\u00e9es<\/td><td>D\u00e9bit binaire et format de trame<\/td><td>D\u00e9bit en bauds, parit\u00e9 et format de trame<\/td><\/tr><tr><td>Protocole applicatif<\/td><td>Ensemble de messages requis<\/td><td>Carte de registres ou d\u00e9finition de messages<\/td><\/tr><tr><td>Preuves produit<\/td><td>Batterie, onduleur et micrologiciel nomm\u00e9s<\/td><td>Batterie, onduleur et micrologiciel nomm\u00e9s<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Couches de compatibilit\u00e9 de communication<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic.jpg\" alt=\"Communication onduleur-batterie CAN vs RS485 : sch\u00e9ma de connexion en parall\u00e8le d&#039;un onduleur hybride 16 kW\" class=\"wp-image-2741\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-300x300.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-150x150.jpg 150w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-768x768.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-12x12.jpg 12w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-600x600.jpg 600w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-800x800.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/16kw-Hybrid-inverter-parallel-connection-schematic-100x100.jpg 100w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Les acheteurs d\u00e9finissant le p\u00e9rim\u00e8tre initial peuvent comparer ces exigences avec la <a href=\"https:\/\/hmxenergy.com\/fr\/produit\/batterie-lithium-fer-phosphate-512-v-280-ah-montee-au-sol-batterie-de-stockage-denergie-domestique-de-15-kwh\/\">Batterie LiFePO4 sur pied de 15 kWh<\/a>. La page est une r\u00e9f\u00e9rence produit ou projet ; l'ad\u00e9quation finale n\u00e9cessite toujours une sp\u00e9cification de projet \u00e9crite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les travaux de sp\u00e9cification et d'acceptation, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/116482\" target=\"_blank\" rel=\"noopener noreferrer\">Port\u00e9e de s\u00e9curit\u00e9 des onduleurs IEC 62109-2<\/a> fournit une r\u00e9f\u00e9rence ind\u00e9pendante. IEC 62109-2 traite des exigences de s\u00e9curit\u00e9 pour les onduleurs photovolta\u00efques, y compris la protection contre les dangers \u00e9lectriques, thermiques, d'incendie et m\u00e9caniques.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Mettre en service la combinaison nomm\u00e9e batterie-onduleur-micrologiciel<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'offre commerciale doit indiquer ses hypoth\u00e8ses, exclusions et p\u00e9rim\u00e8tre de mesure. Les acheteurs peuvent alors comparer les syst\u00e8mes sur la m\u00eame base et maintenir les modifications de conception ult\u00e9rieures sous contr\u00f4le documentaire.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Test<\/th><th>R\u00e9sultat attendu<\/th><th>Test de d\u00e9faillance<\/th><\/tr><\/thead><tbody><tr><td>Limite de puissance<\/td><td>L'onduleur respecte la limite de charge\/d\u00e9charge de la batterie<\/td><td>La limite devient conservatrice en cas de perte de donn\u00e9es<\/td><\/tr><tr><td>\u00c9tat de charge<\/td><td>Les affichages restent coh\u00e9rents<\/td><td>Les donn\u00e9es invalides sont signal\u00e9es<\/td><\/tr><tr><td>Transfert d'alarme<\/td><td>Les d\u00e9fauts de batterie apparaissent correctement<\/td><td>Aucun faux \u00e9tat normal<\/td><\/tr><tr><td>Red\u00e9marrage<\/td><td>La communication se r\u00e9tablit dans l'ordre<\/td><td>D\u00e9lai d'attente et nouvelle tentative d\u00e9finis<\/td><\/tr><tr><td>Batteries en parall\u00e8le<\/td><td>Les limites agr\u00e9g\u00e9es sont correctes<\/td><td>L'isolation d'une unit\u00e9 est g\u00e9r\u00e9e en toute s\u00e9curit\u00e9<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Plan de test sur banc<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Points d'action pour l'\u00e9quipe projet<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Utilisez le c\u00e2ble de communication fourni ou v\u00e9rifiez chaque broche.<\/li><li>Enregistrez les r\u00e9glages des commutateurs DIP, de l'adresse et de la terminaison.<\/li><li>Tester l'\u00e9tat de charge faible et \u00e9lev\u00e9, pas seulement le fonctionnement au repos.<\/li><li>Geler les versions de firmware de travail avant exp\u00e9dition et d\u00e9finir la responsabilit\u00e9 des mises \u00e0 jour.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Avant le gel de la conception, l'\u00e9quipe projet doit examiner <a href=\"https:\/\/www.energy.gov\/cmei\/femp\/articles\/battery-energy-storage-system-procurement-checklist\" target=\"_blank\" rel=\"noopener noreferrer\">la liste de contr\u00f4le d'approvisionnement BESS du DOE am\u00e9ricain<\/a>. La liste de contr\u00f4le du D\u00e9partement de l'\u00e9nergie des \u00c9tats-Unis s\u00e9pare le d\u00e9veloppement pr\u00e9coce du projet, les sp\u00e9cifications techniques et les travaux d'interconnexion pour les syst\u00e8mes lithium-ion commerciaux.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Probl\u00e8mes de compatibilit\u00e9 derri\u00e8re un connecteur familier<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ce sont les objections pratiques et les modes de d\u00e9faillance les plus susceptibles de bloquer une approbation, de retarder la mise en service ou de cr\u00e9er un appel de service \u00e9vitable pour les distributeurs de batteries, les installateurs d'onduleurs et les int\u00e9grateurs de syst\u00e8mes.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>CAN ou RS485 est confondu avec un protocole d'application complet.<\/li><li>Le brochage, la terminaison, l'adressage ou le firmware diff\u00e8rent de la combinaison test\u00e9e.<\/li><li>L'onduleur continue avec des limites dangereuses ou obsol\u00e8tes apr\u00e8s une perte de communication.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Questions que l'acheteur doit poser avant l'approbation<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Quels mod\u00e8les nomm\u00e9s et quels firmwares ont \u00e9t\u00e9 test\u00e9s sur banc ?<\/li><li>Quel c\u00e2ble, brochage et terminaison sont requis ?<\/li><li>Quelle limite conservatrice s'applique si les donn\u00e9es de la batterie sont perdues ?<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Valider la pile de protocoles compl\u00e8te, pas le nom du port<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cr\u00e9er une fiche de compatibilit\u00e9 avec le mod\u00e8le de batterie, le mod\u00e8le d'onduleur, la carte de communication, le firmware, la r\u00e9f\u00e9rence de c\u00e2ble ou le brochage, le protocole s\u00e9lectionn\u00e9 et les r\u00e9glages de commutateurs requis. CAN et RS485 d\u00e9finissent les couches inf\u00e9rieures de communication ; les produits doivent n\u00e9anmoins s'accorder sur les messages, les registres, les unit\u00e9s, la mise \u00e0 l'\u00e9chelle, la temporisation et le comportement en cas de d\u00e9faut.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un examen concret au niveau de l'\u00e9quipement, appliquez les v\u00e9rifications ci-dessus au <a href=\"https:\/\/hmxenergy.com\/fr\/produit\/onduleur-solaire-hmx-48v6-5kw-12kw-ip20\/\">Plateforme d'onduleur 48V de 6,5 kW \u00e0 12 kW<\/a> et demandez confirmation pour les conditions du site et le mode d'exploitation pr\u00e9vus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les tests sur banc doivent couvrir l'\u00e9tat de charge, les limites dynamiques de charge et de d\u00e9charge, les restrictions de temp\u00e9rature, les avertissements, les alarmes d'arr\u00eat et le red\u00e9marrage. Comparer les valeurs sur les deux produits et, lorsque possible, dans le trafic captur\u00e9 ou le journal de service. Un \u00e9cran de repos normal constitue une preuve faible, car de nombreuses limites importantes n'apparaissent que pendant la charge, la d\u00e9charge ou les d\u00e9fauts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour l'examen final des preuves, utiliser <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29224\" target=\"_blank\" rel=\"noopener noreferrer\">Champ d'application de l'IEC 63056:2020<\/a> comme contr\u00f4le de source. L'IEC 63056 ajoute des exigences de s\u00e9curit\u00e9 pour les cellules et batteries secondaires au lithium utilis\u00e9es dans les syst\u00e8mes de stockage d'\u00e9nergie \u00e9lectrique jusqu'\u00e0 1 500 V DC nominal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00e9brancher le c\u00e2ble, mettre un appareil hors tension puis sous tension et introduire une limite de batterie contr\u00f4l\u00e9e. L'onduleur doit passer \u00e0 l'\u00e9tat s\u00fbr document\u00e9, signaler les donn\u00e9es invalides et r\u00e9cup\u00e9rer selon la s\u00e9quence approuv\u00e9e. Geler le firmware de travail avant exp\u00e9dition et d\u00e9finir qui est autoris\u00e9 \u00e0 mettre \u00e0 jour l'un ou l'autre produit ult\u00e9rieurement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comment appliquer cela sur un projet en cours<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Identifier la combinaison nomm\u00e9e de mat\u00e9riel et de firmware.<\/li><li>V\u00e9rifier le brochage, la terminaison, l'adresse et le protocole d'application.<\/li><li>Tester les limites dynamiques, les alarmes, la perte de communication et le red\u00e9marrage.<\/li><li>Sauvegarder les param\u00e8tres et d\u00e9finir le contr\u00f4le des modifications pour les mises \u00e0 jour futures.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Enregistrer chaque param\u00e8tre de communication et chaque \u00e9tape de r\u00e9cup\u00e9ration<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilit\u00e9 et la s\u00e9curit\u00e9 d\u00e9pendent de l'\u00e9quipement tel qu'install\u00e9, et non seulement d'un choix de catalogue. Conserver les identifiants de mod\u00e8le et de firmware, les sch\u00e9mas de c\u00e2blage et de protection, les d\u00e9gagements physiques, les param\u00e8tres et les conditions d'essai. Les interventions de service ult\u00e9rieures doivent partir de cette r\u00e9f\u00e9rence et enregistrer chaque modification approuv\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les m\u00eames questions de preuve et d'acceptation peuvent \u00eatre utilis\u00e9es lors de l'\u00e9valuation du projet de stockage d'HMX <a href=\"https:\/\/hmxenergy.com\/fr\/guide-dachat-pour-onduleurs-hybrides-solaires\/\">Guide d'achat d'onduleur hybride<\/a>; les informations du catalogue doivent \u00eatre reconcili\u00e9es avec la quotation contr\u00f4l\u00e9e et les dessins.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00c9quipements, firmwares, accessoires, c\u00e2bles et param\u00e8tres de communication nomm\u00e9s.<\/li><li>Sch\u00e9mas \u00e9lectriques et physiques tels que construits, avec points d'isolement identifi\u00e9s.<\/li><li>R\u00e9sultats de mise en service pour le fonctionnement normal, les limites et les \u00e9tats de d\u00e9faillance s\u00e9lectionn\u00e9s.<\/li><li>Sauvegardes, photographies, journal des modifications et proc\u00e9dure de r\u00e9cup\u00e9ration pour technicien.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Apr\u00e8s une intervention de service ou sur le firmware, comparer le syst\u00e8me retourn\u00e9 \u00e0 la r\u00e9f\u00e9rence approuv\u00e9e et r\u00e9p\u00e9ter les tests concern\u00e9s. Cela acc\u00e9l\u00e8re le d\u00e9pannage ult\u00e9rieur et \u00e9vite qu'une modification terrain non document\u00e9e n'invalide une conclusion de compatibilit\u00e9 ou de s\u00e9curit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vid\u00e9o associ\u00e9e sur l'\u00e9quipement HMX<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cette vid\u00e9o sur l'\u00e9quipement est incluse car elle correspond au mat\u00e9riel ou \u00e0 la configuration abord\u00e9s ici. Il s'agit d'un support visuel compl\u00e9mentaire, et non d'une certification tierce ou d'une preuve de performance pour un autre projet.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\"><iframe title=\"Vid\u00e9o technique HMX Energy\" width=\"960\" height=\"540\" src=\"https:\/\/www.youtube.com\/embed\/9NrRER9Tsew\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/div><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1-1024x768.jpg\" alt=\"Communication onduleur-batterie CAN vs RS485 : test de vieillissement pour chaque batterie finie avant livraison\" class=\"wp-image-2423\" srcset=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1-1024x768.jpg 1024w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1-300x225.jpg 300w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1-768x576.jpg 768w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1-16x12.jpg 16w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1-800x600.jpg 800w, https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Aging-test-for-every-finished-battery-before-delivery-1.jpg 1440w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">En cas d'\u00e9chec de communication<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lorsqu'un d\u00e9faut survient, conserver les journaux et identifier si la cause est le c\u00e2blage, la configuration, le firmware, le protocole ou un \u00e9v\u00e9nement de protection r\u00e9el avant de modifier les param\u00e8tres.<\/p>","protected":false},"excerpt":{"rendered":"<p>Comparez CAN et RS485 pour la communication entre batterie et onduleur, puis v\u00e9rifiez les protocoles, les brochages, les terminaisons, les limites et le comportement en cas de d\u00e9faillance.<\/p>","protected":false},"author":4,"featured_media":2614,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3303","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"HMX ENERGY\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"HMX Energy Co., Ltd -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"CAN vs RS485 Battery Links: What Installers Must Commission\" \/>\n\t\t<meta property=\"og:description\" content=\"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"740\" \/>\n\t\t<meta property=\"og:image:height\" content=\"495\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-04T14:05:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-04T00:50:09+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"CAN vs RS485 Battery Links: What Installers Must Commission\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#blogposting\",\"name\":\"CAN vs RS485 Battery Links: What Installers Must Commission\",\"headline\":\"CAN vs RS485 Battery Links: What Installers Must Commission\",\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Field-wiring-real\\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank.jpg\",\"width\":800,\"height\":753,\"caption\":\"Field wiring real\\u2011shot of IP65 48V solar inverter connected with LiFePO4 battery bank\"},\"datePublished\":\"2026-10-04T14:05:00+00:00\",\"dateModified\":\"2026-10-04T00:50:09+00:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#webpage\"},\"articleSection\":\"Blog&amp;News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"position\":2,\"name\":\"Blog&amp;News\",\"item\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#listItem\",\"name\":\"CAN vs RS485 Battery Links: What Installers Must Commission\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#listItem\",\"position\":3,\"name\":\"CAN vs RS485 Battery Links: What Installers Must Commission\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/category\\\/blog\\\/#listItem\",\"name\":\"Blog&amp;News\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#organization\",\"name\":\"HMX Energy Co., Ltd\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/\",\"telephone\":\"+8613310869219\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/HM-logo.png\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#organizationLogo\",\"width\":740,\"height\":495,\"caption\":\"HM logo\"},\"image\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/people\\\/Huiming-green-ennergy\\\/100091938723333\\\/\",\"https:\\\/\\\/www.instagram.com\\\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/shenzhen-hmx-new-energy-co-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/\",\"name\":\"HMX ENERGY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#webpage\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/\",\"name\":\"CAN vs RS485 Battery Links: What Installers Must Commission\",\"description\":\"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/author\\\/hmxenergy\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Field-wiring-real\\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank.jpg\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#mainImage\",\"width\":800,\"height\":753,\"caption\":\"Field wiring real\\u2011shot of IP65 48V solar inverter connected with LiFePO4 battery bank\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/can-vs-rs485-battery-inverter\\\/#mainImage\"},\"datePublished\":\"2026-10-04T14:05:00+00:00\",\"dateModified\":\"2026-10-04T00:50:09+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/\",\"name\":\"HMX Energy Co., Ltd\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/hmxenergy.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Liaisons de batterie CAN vs RS485 : ce que les installateurs doivent mettre en service","description":"V\u00e9rifier la communication entre la batterie et l'onduleur en examinant la couche physique, le brochage, le protocole, l'adressage, le micrologiciel, les alarmes, le comportement de repli et les enregistrements de tests.","canonical_url":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#blogposting","name":"CAN vs RS485 Battery Links: What Installers Must Commission","headline":"CAN vs RS485 Battery Links: What Installers Must Commission","author":{"@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author"},"publisher":{"@id":"https:\/\/hmxenergy.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank.jpg","width":800,"height":753,"caption":"Field wiring real\u2011shot of IP65 48V solar inverter connected with LiFePO4 battery bank"},"datePublished":"2026-10-04T14:05:00+00:00","dateModified":"2026-10-04T00:50:09+00:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#webpage"},"isPartOf":{"@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#webpage"},"articleSection":"Blog&amp;News"},{"@type":"BreadcrumbList","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/hmxenergy.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/category\/blog\/#listItem","name":"Blog&amp;News"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/category\/blog\/#listItem","position":2,"name":"Blog&amp;News","item":"https:\/\/hmxenergy.com\/fr\/category\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#listItem","name":"CAN vs RS485 Battery Links: What Installers Must Commission"},"previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#listItem","position":3,"name":"CAN vs RS485 Battery Links: What Installers Must Commission","previousItem":{"@type":"ListItem","@id":"https:\/\/hmxenergy.com\/fr\/category\/blog\/#listItem","name":"Blog&amp;News"}}]},{"@type":"Organization","@id":"https:\/\/hmxenergy.com\/fr\/#organization","name":"HMX Energy Co., Ltd","url":"https:\/\/hmxenergy.com\/fr\/","telephone":"+8613310869219","logo":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#organizationLogo","width":740,"height":495,"caption":"HM logo"},"image":{"@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","https:\/\/www.instagram.com\/hmxenergy?igsh=MWZkY293OG90c3J3MQ&utm_source=qr","https:\/\/www.linkedin.com\/company\/shenzhen-hmx-new-energy-co-ltd\/"]},{"@type":"Person","@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author","url":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/","name":"HMX ENERGY"},{"@type":"WebPage","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#webpage","url":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/","name":"CAN vs RS485 Battery Links: What Installers Must Commission","description":"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/hmxenergy.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#breadcrumblist"},"author":{"@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author"},"creator":{"@id":"https:\/\/hmxenergy.com\/fr\/author\/hmxenergy\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2026\/09\/Field-wiring-real\u2011shot-of-IP65-48V-solar-inverter-connected-with-LiFePO4-battery-bank.jpg","@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#mainImage","width":800,"height":753,"caption":"Field wiring real\u2011shot of IP65 48V solar inverter connected with LiFePO4 battery bank"},"primaryImageOfPage":{"@id":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/#mainImage"},"datePublished":"2026-10-04T14:05:00+00:00","dateModified":"2026-10-04T00:50:09+00:00"},{"@type":"WebSite","@id":"https:\/\/hmxenergy.com\/fr\/#website","url":"https:\/\/hmxenergy.com\/fr\/","name":"HMX Energy Co., Ltd","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/hmxenergy.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"HMX Energy Co., Ltd -","og:type":"article","og:title":"CAN vs RS485 Battery Links: What Installers Must Commission","og:description":"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.","og:url":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/","og:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:secure_url":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png","og:image:width":740,"og:image:height":495,"article:published_time":"2026-10-04T14:05:00+00:00","article:modified_time":"2026-10-04T00:50:09+00:00","article:publisher":"https:\/\/www.facebook.com\/people\/Huiming-green-ennergy\/100091938723333\/","twitter:card":"summary_large_image","twitter:title":"CAN vs RS485 Battery Links: What Installers Must Commission","twitter:description":"Verify battery-to-inverter communication by physical layer, pinout, protocol, addressing, firmware, alarms, fallback behavior and test records.","twitter:image":"https:\/\/hmxenergy.com\/wp-content\/uploads\/2025\/04\/HM-logo.png"},"aioseo_meta_data":{"post_id":"3303","title":"Liaisons de batterie CAN vs RS485 : ce que les installateurs doivent mettre en service","description":"V\u00e9rifier la communication entre la batterie et l'onduleur en examinant la couche physique, le brochage, le protocole, l'adressage, le micrologiciel, les alarmes, le comportement de repli et les enregistrements de tests.","keywords":null,"keyphrases":{"focus":{"keyphrase":"CAN vs RS485 battery inverter communication","score":0,"analysis":[]},"additional":[]},"focus_keyword":"CAN vs RS485 battery inverter communication","additional_keywords":null,"truseo_locale":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-30 03:33:54","updated":"2026-10-04 14:05:42"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/fr\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/hmxenergy.com\/fr\/category\/blog\/\" title=\"Blog&amp;News\">Blog&amp;News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tCAN vs RS485 Battery Links: What Installers Must Commission\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/hmxenergy.com\/fr\/"},{"label":"Blog&amp;News","link":"https:\/\/hmxenergy.com\/fr\/category\/blog\/"},{"label":"CAN vs RS485 Battery Links: What Installers Must Commission","link":"https:\/\/hmxenergy.com\/fr\/can-vs-rs485-battery-inverter\/"}],"_links":{"self":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts\/3303","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/comments?post=3303"}],"version-history":[{"count":6,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts\/3303\/revisions"}],"predecessor-version":[{"id":3479,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/posts\/3303\/revisions\/3479"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/media\/2614"}],"wp:attachment":[{"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/media?parent=3303"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/categories?post=3303"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hmxenergy.com\/fr\/wp-json\/wp\/v2\/tags?post=3303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}