HMX Energy C&I energy storage system integrates LiFePO4 battery modules and high-performance bidirectional PCS. We deliver reliable energy storage solutions for manufacturing plants, industrial parks, commercial complexes and data centres. Available in indoor cabinet and outdoor container formats with flexible capacity scaling. Full-project delivery and localised technical support are available for overseas projects.

Store cheap off-peak grid power, discharge during high-price peak hours to cut overall electricity expenditure.
Smooth power spikes, effectively reduce maximum demand charges for factories and industrial facilities.
Adopt lithium iron phosphate battery chemistry with multi-layer protection for long-cycle stable operation.
Real-time system status, remote data check, alarm notification and performance statistics via cloud platform.
Pre-integrated cabinet & container units, shorten site construction and commissioning cycle.
Cover solution design, product supply, technical guidance, commissioning and after-sales support.
The H098 cabinet series covers five capacity levels from 50.68 kWh to 316.4 kWh. This page features the 107.5 kWh air-cooled cabinet. All models share IP55 protection, RS485 / CAN communication and the same certification package.
| Voce | H098-50kWh | H098-100kWh | H098-150kWh | H098-215kWh | H098-315kWh |
|---|---|---|---|---|---|
| Tensione nominale | 563.2 Vd.c | 537.6 Vd.c | 768 Vd.c | 768 Vd.c | 768 Vd.c |
| Intervallo di tensione | 440-642.4 Vd.c | 420-537.6 Vd.c | 600-876 Vd.c | 672-864 Vd.c | 672-864 Vd.c |
| Capacità nominale | 90 Ah | 200 Ah | 206 Ah | 280 Ah | 412 Ah |
| Rated energy | 50.68 kWh | 107.5 kWh | 158 kWh | 215 kWh | 316.4 kWh |
| Rated charge current | 45 A | 100 A | 206 A | 140 A | 206 A |
| Rated discharge current | 45 A | 100 A | 206 A | 140 A | 206 A |
| Size (L × W × H) | W819 × D900 × H1964 (mm) | W1228 × D1125 × H2084 (mm) | W1600 × D1247 × H2414 (mm) | W1910 × D1297 × H2414 (mm) | W2153 × D1297 × H2414 (mm) |
| AC output voltage | 400 V (-20%~+15%) | 400 V (-20%~+15%) | 400 V (-20%~+15%) | 320-460 V | 320-460 V |
| Rated input voltage | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V |
| Rated output voltage | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V | 3W+N+PE; AC 400 V |
| Frequenza nominale | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Rated output current | 36.2 A | 72.5 A | 138 A | 138 A | 276 A |
| Potenza nominale | 25 kW | 50 kW | 100 kW | 100 kW | 200 kW |
| Maximum PV input voltage | 850 V | 850 V | 850 V | 850 V | 850 V |
| Maximum PV power | 15 kW + 15 kW | 38.4 kW + 38.4 kW | 120 kW | 120 kW | 240 kW |
| MPPT operating voltage range | 200 V-800 V | 200 V-800 V | 200 V-950 V | 200 V-950 V | 200 V-950 V |
| MPPT full-load voltage range | 450 V-750 V | 450 V-750 V | 650 V-750 V | 650 V-750 V | 650 V-750 V |
| Peso | 900 kg | 1700 kg | 2300 kg | 2850 kg | 3500 kg |
| Comunicazione | RS485 / CAN | RS485 / CAN | RS485 / CAN | RS485 / CAN | RS485 / CAN |
| Altitude | ≤2000 m | ||||
| Protection class / IP rating | IP55 | ||||
| Charging temperature range | 0°C ~ 50°C | ||||
| Discharging temperature range | -20°C ~ 55°C | ||||
| Certification standards | IEC 63056 / IEC 62477-1 / EN61000-6 / IEC 62933-5-2-2020 / IEC 62933-2-1:2017 / RoHS 2.0 / UN38.3 / MSDS | ||||

Photovoltaic panels generate DC solar power. The bidirectional PCS completes AC-DC power conversion, and energy is stored in LiFePO4 battery banks.
During high-tariff peak periods or grid failure, the stored energy discharges to supply factory and commercial loads. This delivers peak-valley arbitrage, demand-charge reduction and uninterrupted backup power for your facility.

Peak-valley arbitrage plus demand-charge control for production lines. The cabinet shaves peak load, cuts maximum demand charges and keeps critical equipment running through grid disturbances.

Reliable UPS-grade backup power for critical IT infrastructure. Instant switchover protects servers and network equipment from outage-related downtime and data loss.

Ubicazione: Filippine
Scala del sistema: Accumulo energetico C&I in container da 4MWh
Funzione principale: Arbitraggio picco-valle e alimentazione di backup
Lo stabilimento produttivo ha adottato il nostro ESS in container per esterni per ridurre gli oneri di domanda e garantire l'alimentazione durante le interruzioni di rete.

Ubicazione: Mali
Scala del sistema: 215kWh CabinetType Energy Storage
Funzione principale: Aimed at Mali’s pain points of limited grid coverage and frequent power outages (causing food spoilage in malls, life disruption in villas, safety risks at gas stations), we launched a 100kW/215kWh pure off-grid energy storage system, realizing "self-generation for self-use + parallelizable expansion" and 24/7 uninterrupted power supply.

"PV generation → energy storage → nighttime bus charging" closed loop, 100% off-grid
Ubicazione: Cina
Scala del sistema: Array FV da 625kW + sistema di accumulo energetico da 1MWh
Funzione principale: Responds to "Dual Carbon" strategy & urban green transportation.
Energy Attribute: From "grid-dependent power sales" to "100% self-consumption" (solves peak-valley price/grid load issues)
Scenario Adaptation: Matches buses’ "day operation, night charging" via time-shifted energy supply (no municipal power needed)
Benefits: From single economic benefit to "ecology + economy + operation" triple value
Select the proper energy storage capacity according to your site’s actual load condition:
100–300 kWh cabinet-type energy storage
500–1000 kWh container-type energy storage
Above 1 MWh, customised container ESS solution
Contact our engineering team for free site evaluation and a custom-tailored solution.
C&I energy storage helps business users realise peak-valley arbitrage, reduce demand charges, provide emergency backup power and improve the self-consumption rate of on-site solar PV systems. It is widely used for factories, warehouses, commercial buildings and industrial parks.
Required capacity depends on your maximum load, local electricity tariff rules and target functions. Our engineers can offer a capacity suggestion after you provide your site load data.
Payback is mainly affected by the local electricity price difference, site load profile and system scale. In most Southeast Asia markets, the payback period ranges from 3-6 years.
Sì. Il nostro sistema ESS C&I può collegarsi agli impianti fotovoltaici esistenti per costruire sistemi ibridi solare-accumulo senza sostituire i vostri pannelli solari attuali.
We provide remote technical guidance, an operation manual, spare parts support and local partner-assisted on-site commissioning service for overseas commercial & industrial energy-storage projects.
Cerchi un preventivo per il tuo progetto di accumulo energetico industriale o commerciale?
Si prega di condividere le informazioni sul carico del sito, la tariffa elettrica locale e i requisiti funzionali. Il nostro team di ingegneria professionale risponderà alla vostra richiesta entro 24 ore lavorative.